• Eur J Cardiothorac Surg · May 2014

    Quicker yet safe: skeletonization of 1640 internal mammary arteries with harmonic technology in 965 patients.

    • Teresa M Kieser, M Sarah Rose, Uthman Aluthman, and Kishan Narine.
    • Department of Cardiac Sciences, LIBIN Cardiovascular Institute of Alberta, University of Calgary, Calgary, Alberta, Canada.
    • Eur J Cardiothorac Surg. 2014 May 1; 45 (5): e142-50.

    ObjectivesSkeletonization of the internal mammary artery (IMA) facilitates arterial grafting and has been shown to reduce deep sternal infection but is more time-consuming and tedious than pedicle harvest. We wished to determine if use of harmonic technology (HT) facilitates skeletonization of the IMA and is as safe as the conventional technique of skeletonization.MethodsIn a consecutive series of 1057 patients with isolated coronary artery bypass graft (CABG) surgery from 2003 to 2013, adverse events and recorded harvest times were compared between harmonic (965 patients) and non-harmonic patients (86 patients).ResultsHT was used to harvest 1640 IMAs in 965 (91%) of 1057 consecutive CABG patients and skeletonization with the traditional technique (use of an electrocautery tip as a dissector) was used to harvest 147 IMAs in 86 patients. Six patients had no IMA harvested with this surgery (4 patients had an IMA used from a previous CABG, 1 had no disease of the left anterior descending coronary artery and 1 patient was in cardiogenic shock precluding IMA use). Excluding patients with single-vessel disease, 730/987 (74%) of patients received bilateral IMAs. Demographics of patients with and without harmonic skeletonization, respectively, were the following: mean age: 64.7 vs 67.7 years; diabetes: 33 vs 34%; women: 21 vs 26% and median European System for Cardiac Operative Risk Evaluation: 2.9 vs 3.2. The mean harvest time for 77 non-harmonic skeletonized mammary arteries (49 surgeries) was 32.2 min (95% confidence interval (CI): 30.1, 34.3), for harmonic skeletonized arteries after 450 surgeries was 28.4 min, (95% CI: 27.8, 29.1) and in the last 100 IMAs harvested for the isolated harmonic device use/mammary was 15.4 min (95% CI: 14.0, 16.7). Major adverse events for patients with and without harmonic skeletonization, respectively, were: reoperation for bleeding: 2.7 vs 3.5% (difference = 0.8%, 95% CI: -3.2, 4.8); damaged mammaries: 0.4 vs 0.7% (difference = 0.3%, 95% CI: -1.0, 1.7); deep sternal infection: 1.6 vs 1.2% (difference = -0.4%, 95% CI: -2.8, 2.0) and perioperative infarction: 1.7 vs 2.3% (difference = 0.7%, 95% CI: -2.6, 4.0).ConclusionIn this largest series to date of harmonic IMA skeletonization, this technique results in rare damage, is quicker and with a comparable adverse event rate compared with the non-harmonic method.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.