• Am. J. Kidney Dis. · Sep 1999

    Diffusive and convective solute clearances during continuous renal replacement therapy at various dialysate and ultrafiltration flow rates.

    • S Brunet, M Leblanc, D Geadah, D Parent, S Courteau, and J Cardinal.
    • Intensive Care Units, Maisonneuve-Rosemont Hospital, Montreal, Canada.
    • Am. J. Kidney Dis. 1999 Sep 1; 34 (3): 486-92.

    AbstractClearances of several solutes (urea, creatinine, phosphate, urates, beta(2)-microglobulin [beta(2)-M]) were measured during venovenous continuous renal replacement therapy (CRRT) at various ultrafiltration (Q(UF); 0 to 2 L/h) and dialysate flow rates (Q(D); 0 to 2.5 L/h). Preset Multiflow-60 and Multiflow-100 hollow-fiber dialysers (M-60 and M-100; Hospal-Gambro, St-Leonard, Canada) were compared (five patients for each type). First, we evaluated the impact of predilution on convective clearances: a progressive decrease in patient clearances, similar for both filters, was observed, reaching a maximum of 15%, 18%, and 19% for urea, urates, and creatinine, respectively, with predilution at a Q(UF) of 2 L/h. Second, we compared convective and diffusive clearances. Because effluent to plasma ratio (E/P) remained at 1 for small solutes (urea, creatinine, phosphate, urates) during convection, clearances were equal to the effluent rate for both dialyzers. However, we observed greater diffusive clearances for small molecules with M-100 than with M-60 at a Q(D) of 1.5 to 2.5 L/h, the difference being more significant as molecular weight increased. For beta(2)-M, diffusive clearance was very low and rapidly reached a plateau of 8 and 12 mL/min for M-60 and M-100, respectively, at a Q(D) greater than 1.5 L/h. Convective clearances for beta(2)-M increased nonlinearly up to 20 +/- 2 mL/min at a progressively greater Q(UF) (from 0.5 to 2 L/h) for both M-60 and M-100. This nonlinear increase was attributed to an increase of almost 40% in E/P for beta(2)-M from a Q(UF) of 0.5 to 2 L/h. Third, the interaction between convection and diffusion was assessed by measuring solute clearances at a fixed Q(UF) (1 and 2 L/h) and variable Q(D) (0.5 to 2.5 L/h). For small molecules, no significant interaction between convection and diffusion was noticed with M-100, whereas only a small interaction was noticed with M-60. However, for beta(2)-M, the addition of diffusion (Q(D), 0.5 to 2.5 L/h) did not result in any significant increase in total clearances over convective clearances for M-60 and M-100. This observation suggests that the diffusive clearances for beta(2)-M observed with M-60 and M-100 at a Q(UF) of 0 L/h and at various Q(D) probably occurs by convective fluxes across the membrane. These results demonstrate that convection is more efficient than diffusion in removing mixed-molecular-weight solutes during CRRT.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…