• Bmc Musculoskel Dis · Oct 2018

    Clinical Trial

    Inter- and intra-rater reliability for measurement of range of motion in joints included in three hypermobility assessment methods.

    • Angela Schlager, Kerstin Ahlqvist, Eva Rasmussen-Barr, Elisabeth Krefting Bjelland, Ronnie Pingel, Christina Olsson, Lena Nilsson-Wikmar, and Per Kristiansson.
    • Department of Public Health and Caring Sciences, Uppsala University, Husargatan 3, Box 564, 752 37, Uppsala, Sweden. angela.schlager@pubcare.uu.se.
    • Bmc Musculoskel Dis. 2018 Oct 17; 19 (1): 376.

    BackgroundComparisons across studies of generalized joint hypermobility are often difficult since there are several classification methods and methodological differences in the performance exist. The Beighton score is most commonly used and has been tested for inter- and intra-rater reliability. The Contompasis score and the Hospital del Mar criteria have not yet been evaluated for reliability. The aim of this study was to investigate the inter- and intra-rater reliability for measurements of range of motion in joints included in these three hypermobility assessment methods using a structured protocol.MethodsThe study was planned in accordance with guidelines for reporting reliability studies. Healthy adults were consecutively recruited (49 for inter- and 29 for intra-rater assessments). Intra-class correlations, two-way random effects model, (ICC 2.1) with 95% confidence intervals, standard error of measurement, percentage of agreement, Cohen's Kappa (κ) and prevalence-adjusted bias-adjusted kappa were calculated for single-joint measured in degrees and for total scores.ResultsThe inter- and intra-rater reliability in total scores were ICC 2.1: 0.72-0.82 and 0.76-0.86 and for single-joint measurements in degrees 0.44-0.91 and 0.44-0.90, respectively. The difference between ratings was within 5 degrees in all but one joint. Standard error of measurement ranged from 1.0 to 6.9 degrees. The inter- and intra-rater reliability for prevalence of positive hypermobility findings the Cohen's κ for total scores were 0.54-0.78 and 0.27-0.78 and in single joints 0.21-1.00 and 0.19-1.00, respectively. The prevalence- and bias adjusted Cohen's κ, increased all but two values.ConclusionsFollowing a structured protocol, the inter- and intra-rater reliability was good-to-excellent for total scores and in all but two single joints, measured in degrees. The inter- and intra-rater reliability for prevalence of positive hypermobility findings was fair-to-almost perfect for total scores and slight-to-almost-perfect in single joints. By using a structured protocol, we attempted to standardize the assessment of range of motion in clinical and in research settings. This standardization could be helpful in the first part of the process of standardizing the tests thus avoiding that assessment of GJH is based on chance.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…