- Berry M van Gelder, Patrick Houthuizen, and Frank A Bracke.
- Department of Cardiology, Catharina Hospital, Michelangelolaan 2, 5623 EJ Eindhoven, the Netherlands. carlgr@cze.nl
- Europace. 2011 Oct 1; 13 (10): 1454-8.
AimsCoronary sinus (CS) lead placement for transvenous cardiac resynchronization therapy (CRT) even combined with transseptal left ventricular (LV) endocardial implantation from a superior approach still does not have 100% success rate. The aim of this study was to assess the feasibility of a femoral transseptal endocardial LV approach pacing in patients in whom a transvenous CS or a transseptal LV endocardial implantation with a superior approach had failed. We report our first experience with LV endocardial lead placement for CRT with a femoral transseptal technique followed by intravascular pull-through to the pectoral location.Methods And ResultsIn 11 patients, 10 males (61.5 ± 9.5 years) with failed CS implant (four patients) or repeated CS lead malfunction (seven patients), a 4.1 French active fixation lead was implanted endocardially in the left ventricle employing a femoral approach using an 8F transseptal sheath combined with a hooked 6F catheter. After successful implantation, the lead was pulled through from the femoral insertion site to the pectoral device location. The LV endocardial implantation was successfully performed in all patients. Stimulation threshold was 0.62 ± 0.33 V, lead impedance 825 ± 127 Ω, and R wave 12.8 ± 8.3 mV. Threshold and lead impedance were stable during follow-up, which varied from 1 to 6 months. No dislodgements were observed and there were no thrombo-embolic events during follow-up.ConclusionThis technique for LV endocardial lead implantation is an alternative for failed CS and superior transseptal attempts using standard techniques and equipment. It is also applicable for pacing sites that are more easily reached from a femoral approach.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.