• Investigative radiology · Mar 2018

    Intravoxel Incoherent Motion Analysis of Abdominal Organs: Application of Simultaneous Multislice Acquisition.

    • Valerie Doan Phi Van, Anton S Becker, Alexander Ciritsis, Caecilia S Reiner, and Andreas Boss.
    • From the Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, Zurich, Switzerland.
    • Invest Radiol. 2018 Mar 1; 53 (3): 179-185.

    PurposeThe aim of this study was to systematically evaluate the accuracy of quantitative intravoxel incoherent motion (IVIM) analysis of the upper abdomen applying simultaneous multislice (SMS) diffusion-weighted imaging (DWI) to reduce acquisition time.Materials And MethodsDiffusion-weighted imaging of parenchymal abdominal organs was performed in 8 healthy volunteers at 3 T using a standard DWI sequence (acceleration factor 1 [AF1]) and an SMS-accelerated echo planar imaging sequence with acceleration factors 2 and 3 (AF2/AF3). Intravoxel incoherent motion analysis was performed with a multistep algorithm for true diffusion coefficient (Dt), pseudodiffusion coefficient (D*), and fraction of perfusion (Fp) measured for the liver, kidney cortex and medulla, pancreas, spleen, and erector spinae muscle. Qualitative and quantitative parameters were compared using a repeated measurement 1-way analysis of variance test and the Bonferroni post hoc method.ResultsSimultaneous multislice DWI provided diagnostic image quality in all volunteers with a reduction of scan time of 50% for AF2 (67% for AF3) compared with the standard sequence. Decent IVIM analysis for Dt, D*, and Fp can be calculated on the images of both the SMS sequences AF2 and AF3 with typical organ characteristics of IVIM; however, systematical deviations from AF1 were observed: Dt values increased and Fp decreased significantly with higher acceleration factor for liver, kidney, pancreas, and muscle (P < 0.05). Fitting curves of higher acceleration factors tend to be more monoexponentially shaped.ConclusionsSimultaneous multislice acceleration provides considerable scan time reduction for upper abdomen DWI with equivalent quality of IVIM analysis compared with the standard nonaccelerated technique. Systematic discrepancies of the true Dt, D*, and Fp for SMS acquisitions need to be considered when comparing to standard DWI sequences.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.