• Lancet Respir Med · Jun 2019

    Randomized Controlled Trial Multicenter Study

    Diagnostic accuracy of whole-body MRI versus standard imaging pathways for metastatic disease in newly diagnosed non-small-cell lung cancer: the prospective Streamline L trial.

    • Stuart A Taylor, Sue Mallett, Simon Ball, Sandy Beare, Gauraang Bhatnagar, Angshu Bhowmik, Peter Boavida, John Bridgewater, Caroline S Clarke, Marian Duggan, Steve Ellis, Robert Glynne-Jones, Vicky Goh, Ashley M Groves, Ayshea Hameeduddin, Sam M Janes, Edward W Johnston, Dow-Mu Koh, Sara Lock, Anne Miles, Stephen Morris, Alison Morton, Neal Navani, Alfred Oliver, Terry O'Shaughnessy, Anwar R Padhani, David Prezzi, Shonit Punwani, Laura Quinn, Hameed Rafiee, Krystyna Reczko, Andrea G Rockall, Peter Russell, Harbir S Sidhu, Nicola Strickland, Kathryn Tarver, Jonathan Teague, Steve Halligan, and Streamline investigators.
    • Centre for Medical Imaging, University College London, London, UK. Electronic address: stuart.taylor@ucl.ac.uk.
    • Lancet Respir Med. 2019 Jun 1; 7 (6): 523-532.

    BackgroundWhole-body magnetic resonance imaging (WB-MRI) could be an alternative to multi-modality staging of non-small-cell lung cancer (NSCLC), but its diagnostic accuracy, effect on staging times, number of tests needed, cost, and effect on treatment decisions are unknown. We aimed to prospectively compare the diagnostic accuracy and efficiency of WB-MRI-based staging pathways with standard pathways in NSCLC.MethodsThe Streamline L trial was a prospective, multicentre trial done in 16 hospitals in England. Eligible patients were 18 years or older, with newly diagnosed NSCLC that was potentially radically treatable on diagnostic chest CT (defined as stage IIIb or less). Exclusion criteria were severe systemic disease, pregnancy, contraindications to MRI, or histologies other than NSCLC. Patients underwent WB-MRI, the result of which was withheld until standard staging investigations were complete and the first treatment decision made. The multidisciplinary team recorded its treatment decision based on standard investigations, then on the WB-MRI staging pathway (WB-MRI plus additional tests generated), and finally on all tests. The primary outcome was difference in per-patient sensitivity for metastases between standard and WB-MRI staging pathways against a consensus reference standard at 12 months, in the per-protocol population. Secondary outcomes were difference in per-patient specificity for metastatic disease detection between standard and WB-MRI staging pathways, differences in treatment decisions, staging efficiency (time taken, test number, and costs) and per-organ sensitivity and specificity for metastases and per-patient agreement for local T and N stage. This trial is registered with the International Standard Randomised Controlled Trial registry, number ISRCTN50436483, and is complete.FindingsBetween Feb 26, 2013, and Sept 5, 2016, 976 patients were screened for eligibility. 353 patients were recruited, 187 of whom completed the trial; 52 (28%) had metastasis at baseline. Pathway sensitivity was 50% (95% CI 37-63) for WB-MRI and 54% (41-67) for standard pathways, a difference of 4% (-7 to 15, p=0·73). No adverse events related to imaging were reported. Specificity did not differ between WB-MRI (93% [88-96]) and standard pathways (95% [91-98], p=0·45). Agreement with the multidisciplinary team's final treatment decision was 98% for WB-MRI and 99% for the standard pathway. Time to complete staging was shorter for WB-MRI (13 days [12-14]) than for the standard pathway (19 days [17-21]); a 6-day (4-8) difference. The number of tests required was similar WB-MRI (one [1-1]) and standard pathways (one [1-2]). Mean per-patient costs were £317 (273-361) for WBI-MRI and £620 (574-666) for standard pathways.InterpretationWB-MRI staging pathways have similar accuracy to standard pathways, and reduce the staging time and costs.FundingUK National Institute for Health Research.Copyright © 2019 The Author(s). Published by Elsevier Ltd. This is an Open Access article under the CC BY 4.0 license. Published by Elsevier Ltd.. All rights reserved.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…