-
Multicenter Study Comparative Study
Comparison of functional outcome after volar plate fixation with 2.4-mm titanium versus 3.5-mm stainless-steel plate for extra-articular fracture of distal radius.
- J Sebastiaan Souer, David Ring, Stefan Matschke, Laurent Audige, Marta Maren-Hubert, and Jesse Jupiter.
- Hand and Upper Extremity Service, Massachusetts General Hospital, Boston, MA 02114, USA.
- J Hand Surg Am. 2010 Mar 1; 35 (3): 398-405.
PurposeOpen reduction and locked volar plate and screw fixation is a popular treatment method for extra-articular distal radius fractures with dorsal metaphyseal comminution. In this study, we compared the use of a titanium 2.4-mm precontoured plate with that of a stainless-steel oblique 3.5-mm T-shaped plate to test the null hypothesis that there would be no difference in wrist function or upper extremity-specific health status in the internal fixation of AO-type A3.2 distal radius fractures.MethodsWe retrospectively analyzed 24 patients treated with a 2.4-mm titanium plate and 38 patients treated with a 3.5-mm stainless-steel plate for an extra-articular and dorsally angulated distal radius fracture, from data gathered in a prospective cohort study of plate and screw fixation of distal radius fractures. The 2 cohorts were analyzed for differences in motion, grip strength, pain, Gartland and Werley score, Disabilities of the Arm, Shoulder, and Hand score, and Short Form-36 score at 6, 12, and 24 months of follow-up. Group differences and their change over time were determined using regression analysis and the likelihood ratio test.ResultsThere were no significant differences in wrist function and arm-specific health status between patients treated with a 2.4-mm plate and those treated with a 3.5-mm plate at 6, 12, or 24 months of follow-up. However, we observed a trend toward greater wrist flexion at 1 year (66 degrees vs 55 degrees ; p=.07) and greater flexion-extension arc (137 degrees vs 123 degrees ; p=.08) and pronation-supination arc (172 degrees vs 160 degrees ; p=.07) at 24 months after surgery in patients treated with a 2.4-mm plate.ConclusionsPatients with a dorsally angulated extra-articular distal radius facture can expect similar results when treated with either a precontoured 2.4-mm titanium plate or a 3.5-mm stainless-steel T-shaped plate.Type Of Study/Level Of EvidenceTherapeutic III.Copyright 2010. Published by Elsevier Inc.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.