    Inhomogeneous target-dose distributions: a dimension more for optimization?

    • W R De Gersem, S Derycke, C O Colle, C De Wagter, and W J De Neve.
    • Department of Radiotherapy and Nuclear Medicine, University Hospital Gent, Belgium.
    • Int. J. Radiat. Oncol. Biol. Phys. 1999 May 1; 44 (2): 461-8.

    PurposeTo evaluate if the use of inhomogeneous target-dose distributions, obtained by 3D conformal radiotherapy plans with or without beam intensity modulation, offers the possibility to decrease indices of toxicity to normal tissues and/or increase indices of tumor control stage III non-small cell lung cancer (NSCLC).Methods And MaterialsTen patients with stage III NSCLC were planned using a conventional 3D technique and a technique involving noncoplanar beam intensity modulation (BIM). Two planning target volumes (PTVs) were defined: PTV1 included macroscopic tumor volume and PTV2 included macroscopic and microscopic tumor volume. Virtual simulation defined the beam shapes and incidences as well as the wedge orientations (3D) and segment outlines (BIM). Weights of wedged beams, unwedged beams, and segments were determined by optimization using an objective function with a biological and a physical component. The biological component included tumor control probability (TCP) for PTV1 (TCP1), PTV2 (TCP2), and normal tissue complication probability (NTCP) for lung, spinal cord, and heart. The physical component included the maximum and minimum dose as well as the standard deviation of the dose at PTV1. The most inhomogeneous target-dose distributions were obtained by using only the biological component of the objective function (biological optimization). By enabling the physical component in addition to the biological component, PTV1 inhomogeneity was reduced (biophysical optimization). As indices for toxicity to normal tissues, NTCP-values as well as maximum doses or dose levels to relevant fractions of the organ's volume were used. As indices for tumor control, TCP-values as well as minimum doses to the PTVs were used.ResultsWhen optimization was performed with the biophysical as compared to the biological objective function, the PTV1 inhomogeneity decreased from 13 (8-23)% to 4 (2-9)% for the 3D-(p = 0.00009) and from 44 (33-56)% to 20 (9-34)% for the BIM plans (p < 0. 00001). Minimum PTV1 doses (expressed as the lowest voxel-dose) were similar for both objective functions. The mean and maximum target doses were significantly higher with biological optimization for 3D as well as for BIM (all p values < 0.001). Tumor control probability (estimated by TCP1 x TCP2) was 4.7% (3D) and 6.2% (BIM) higher for biological optimization (p = 0.01 and p = 0.00002 respectively). NTCP(lung) as well as the percentage of lung volume exceeding 20 Gy was higher with the use of the biophysical objective function. NTCP(heart) was also higher with the use of the biophysical objective function. The percentage of heart volume exceeding 40 Gy tended to be higher but the difference was not significant. For spinal cord, the maximum dose as well as NTCP(cord) were similar for 3D plans (D(max): p = 0.04; NTCP: p = 0.2) but were significantly lower for BIM (D(max): p = 0.002; NTCP: p = 0.008) if the biophysical objective function was used.ConclusionsWhen using conventional 3D techniques, inhomogeneous dose distributions offer the potential to further increase the probability of uncomplicated local control. When using techniques as BIM that would lead to large escalation of the median and maximum target doses, it seems indicated to limit target-dose inhomogeneity to avoid dose levels that are so high that the safety becomes questionable.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,694,794 articles already indexed!

We guarantee your privacy. Your email address will not be shared.