• Int. J. Radiat. Oncol. Biol. Phys. · Aug 2011

    Comparative Study

    Artifacts in conventional computed tomography (CT) and free breathing four-dimensional CT induce uncertainty in gross tumor volume determination.

    • Gitte Fredberg Persson, Ditte Eklund Nygaard, Per Munck Af Rosenschöld, Ivan Richter Vogelius, Mirjana Josipovic, Lena Specht, and Stine Sofia Korreman.
    • Department of Radiation Oncology, Copenhagen University Hospital, Rigshospitalet, Copenhagen, Denmark. gitte.persson@rh.regionh.dk
    • Int. J. Radiat. Oncol. Biol. Phys. 2011 Aug 1; 80 (5): 1573-80.

    PurposeArtifacts impacting the imaged tumor volume can be seen in conventional three-dimensional CT (3DCT) scans for planning of lung cancer radiotherapy but can be reduced with the use of respiration-correlated imaging, i.e., 4DCT or breathhold CT (BHCT) scans. The aim of this study was to compare delineated gross tumor volume (GTV) sizes in 3DCT, 4DCT, and BHCT scans of patients with lung tumors.Methods And MaterialsA total of 36 patients with 46 tumors referred for stereotactic radiotherapy of lung tumors were included. All patients underwent positron emission tomography (PET)/CT, 4DCT, and BHCT scans. GTVs in all CT scans of individual patients were delineated during one session by a single physician to minimize systematic delineation uncertainty. The GTV size from the BHCT was considered the closest to true tumor volume and was chosen as the reference. The reference GTV size was compared to GTV sizes in 3DCT, at midventilation (MidV), at end-inspiration (Insp), and at end-expiration (Exp) bins from the 4DCT scan.ResultsThe median BHCT GTV size was 4.9 cm(3) (0.1-53.3 cm(3)). Median deviation between 3DCT and BHCT GTV size was 0.3 cm(3) (-3.3 to 30.0 cm(3)), between MidV and BHCT size was 0.2 cm(3) (-5.7 to 19.7 cm(3)), between Insp and BHCT size was 0.3 cm(3) (-4.7 to 24.8 cm(3)), and between Exp and BHCT size was 0.3 cm(3) (-4.8 to 25.5 cm(3)). The 3DCT, MidV, Insp, and Exp median GTV sizes were all significantly larger than the BHCT median GTV size.ConclusionsIn the present study, the choice of CT method significantly influenced the delineated GTV size, on average, leading to an increase in GTV size compared to the reference BHCT. The uncertainty caused by artifacts is estimated to be in the same magnitude as delineation uncertainty and should be considered in the design of margins for radiotherapy.Copyright © 2011 Elsevier Inc. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…