• Int J Clin Pharm · Feb 2015

    Evaluating performance of electronic healthcare records and spontaneous reporting data in drug safety signal detection.

    • Vaishali K Patadia, Martijn J Schuemie, Preciosa Coloma, Ron Herings, Johan van der Lei, Sabine Straus, Miriam Sturkenboom, and Gianluca Trifirò.
    • Department of Medical Informatics, Erasmus University Medical Center, Rotterdam, The Netherlands, v.patadia@erasmusmc.nl.
    • Int J Clin Pharm. 2015 Feb 1; 37 (1): 94-104.

    BackgroundElectronic reporting and processing of suspected adverse drug reactions (ADRs) is increasing and has facilitated automated screening procedures. It is crucial for healthcare professionals to understand the nature and proper use of data available in pharmacovigilance practice.ObjectivesTo (a) compare performance of EU-ADR [electronic healthcare record (EHR) exemplar] and FAERS [spontaneous reporting system (SRS) exemplar] databases in detecting signals using "positive" and "negative" drug-event reference sets; and (b) evaluate the impact of timing bias on sensitivity thresholds by comparing all data to data restricted to the time before a warning/regulatory action.MethodsTen events with known positive and negative reference sets were selected. Signals were identified when respective statistics exceeded defined thresholds. Main outcome measure Performance metrics, including sensitivity, specificity, positive predictive value and accuracy were calculated. In addition, the effect of regulatory action on the performance of signal detection in each data source was evaluated.ResultsThe sensitivity for detecting signals in EHR data varied depending on the nature of the adverse events and increased substantially if the analyses were restricted to the period preceding the first regulatory action. Across all events, using data from all years, a sensitivity of 45-73 % was observed for EU-ADR and 77 % for FAERS. The specificity was high and similar for EU-ADR (82-96 %) and FAERS (98 %). EU-ADR data showed range of PPV (78-91 %) and accuracy (78-72 %) and FAERS data yielded a PPV of 97 % with 88 % accuracy.ConclusionUsing all cumulative data, signal detection in SRS data achieved higher specificity and sensitivity than EHR data. However, when data were restricted to time prior to a regulatory action, performance characteristics changed in a manner consistent with both the type of data and nature of the ADR. Further research focusing on prospective validation of is necessary to learn more about the performance and utility of these databases in modern pharmacovigilance practice.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…