• AJNR Am J Neuroradiol · Oct 1994

    Comparative Study

    Fat-suppressed MR of the orbit and cavernous sinus: comparison of fast spin-echo and conventional spin-echo.

    • S K Mukherji, R P Tart, J Fitzsimmons, C Belden, S McGorray, J Guy, and A A Mancuso.
    • Department of Radiology, University of Florida College of Medicine, Gainesville 32610.
    • AJNR Am J Neuroradiol. 1994 Oct 1; 15 (9): 1707-14.

    PurposeTo compare T2-weighted fat-suppressed fast spin-echo imaging with fat-suppressed conventional spin-echo imaging in the detection of normal intraorbital and pericavernous anatomy and orbital disease, and to determine the efficacy of fat saturation with T2-weighted fast spin-echo imaging of the cavernous sinus.MethodsContrast-to-noise ratios of normal intraorbital anatomy were calculated and compared in 10 consecutive patients using fat-suppressed fast spin-echo and conventional spin-echo T2-weighted images. Contrast-to-noise ratios of common intraorbital lesions were calculated and compared using fat-suppressed fast spin-echo and fat-suppressed conventional spin-echo. Qualitative evaluation was performed and compared for normal intraorbital anatomy using both fat-suppressed fast spin-echo and fat-suppressed conventional spin-echo in 16 patients. Qualitative evaluation for the detection of normal anatomic structures of the pericavernous region was performed and compared using fast spin-echo with and without fat suppression and fat-suppressed conventional spin-echo T2-weighted images in 16 patients. Fat saturation was performed using standard commercially available chemical saturation technique.ResultsReduced imaging time allowed more acquisitions for fat-suppressed fast spin-echo images, which significantly improved visibility of intraorbital and pericavernous anatomy over fat-suppressed conventional spin-echo. Anatomic visibility was also improved because of reduced motion, phase encoding, and susceptibility artifacts. There was no significant difference between contrast-to-noise ratios for fat-suppressed fast spin-echo and fat-suppressed conventional spin-echo imaging of the lateral and medial rectus muscles. Contrast-to-noise ratios of fat suppressed fast spin-echo of orbital disease was significantly greater than contrast-to-noise ratios of fat-suppressed conventional spin-echo. Detection of several normal anatomic structures of the pericavernous region was significantly improved with non-fat-suppressed fast spin-echo over fat-suppressed fast spin-echo because of significantly reduced magnetic susceptibility artifact.ConclusionsFat-suppressed fast spin-echo is superior to fat-suppressed conventional spin-echo for T2-weighted orbital imaging. Non-fat-suppressed fast spin-echo is the preferred pulse sequence for T2-weighted imaging of the cavernous sinus because of the minimal susceptibility artifact.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…