• J Neurointerv Surg · Dec 2017

    Multicenter Study

    Multicenter experience with the new SOFIA Plus catheter as a primary local aspiration catheter for acute stroke thrombectomy.

    • M A Möhlenbruch, C Kabbasch, A Kowoll, E Broussalis, M Sonnberger, M Müller, M Wiesmann, J Trenkler, M Killer-Oberpfalzer, W Weber, A Mpotsaris, M Bendszus, and S Stampfl.
    • Department of Neuroradiology, Heidelberg University Hospital, Heidelberg, Germany.
    • J Neurointerv Surg. 2017 Dec 1; 9 (12): 1223-1227.

    IntroductionThe direct aspiration first pass technique (ADAPT) has been introduced as a rapid and safe endovascular treatment strategy in patients with ischemic stroke.ObjectiveTo determine the technical feasibility, safety, and functional outcome with ADAPT using the new large-bore 6F SOFIA Plus catheter.MethodsA retrospective analysis of prospectively collected data from six university hospitals was performed. The following parameters of all acute stroke procedures (June 2015- January 2016) using the SOFIA Plus catheter were analyzed: accessibility of the thrombus with the catheter, recanalization success (Thrombolysis in Cerebral Infarction ≥2b), time to recanalization, procedure-related complications. Furthermore, National Institutes of Health Stroke Scale (NIHSS) scores at presentation and discharge and the modified Rankin scale (mRS) score at 90 days were recorded.Results85 patients were treated using the SOFIA Plus catheter. The occlusion site was the anterior circulation in 94.1%. Median baseline NIHSS score was 18. In 64.7%, ADAPT alone was successful after a median procedure time of 21 min. With additional use of stent retrievers in the remaining cases, the recanalization rate was 96.5%. No catheter-related complications such as dissections were observed. Thrombus migration to a new vascular territory occurred in 4.7% and symptomatic hemorrhage in 4.7%. After 3 months, mRS 0-2 was achieved in 49.4%. Mortality rate was 20%.ConclusionsIn the majority of cases, thrombus aspiration using the SOFIA Plus catheter results in successful recanalization after a short procedure time. With additional use of stent retrievers, a high recanalization rate can be achieved (96.5%). The complication rate was in line with those of previous publications.Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        

    hide…