• Journal of anesthesia · Dec 2021

    Changes in peripheral perfusion index during intraoperative end-expiratory occlusion tests do not predict the response to fluid administration in patients undergoing lung protective ventilation.

    • Yusuke Iizuka, Masamitsu Sanui, Yuji Otsuka, Koichi Yoshinaga, Takeshi Nakatomi, and Alan Kawarai Lefor.
    • Department of Anesthesiology and Critical Care Medicine, Jichi Medical University Saitama Medical Center, 1-847 Amanuma, Omiya-ku, Saitama, Saitama, 330-8503, Japan. zukarinn@gmail.com.
    • J Anesth. 2021 Dec 1; 35 (6): 837843837-843.

    IntroductionThe end-expiratory occlusion test (EEOT) may predict the response to fluid administration in patients undergoing lung-protective ventilation, but arterial catheter insertion is necessary to evaluate changes in stroke volume (SV). The peripheral perfusion index is a potential noninvasive alternative to evaluate SV. The aim of this study is to investigate whether changes in perfusion index during an intraoperative EEOT can predict the response to fluid administration in patients undergoing lung-protective ventilation (tidal volume 7 ml/kg predicted body weight).MethodsForty-one elective surgical patients were enrolled. The SV and perfusion index were recorded before (baseline), during a 40-s EEOT and after volume expansion (250 ml of lactated Ringer's solution over 10 min). Patients with an increase in SV greater than 10% after volume expansion were defined as responders. ΔPI (change in perfusion index between baseline and 20 (ΔPI20) or 40 s (ΔPI40) after the beginning of EEOT were calculated using: ΔPI20 (%) = [(PI at 20 s after EEOT beginning - PIbaseline)/PIbaseline] × 100, ΔPI40 (%) = [(PI at 40 s after EEO beginning - PIbaseline)/PIbaseline] × 100).ResultsSixteen patients were responders, and 25 were non-responders. The area under the receiver operating characteristics curves generated for ΔPI20 and ΔPI40 to predict response to a fluid challenge were 0.561 (95% CI 0.374-0.749) and 0.688 (95% CI 0.523-0.852), respectively.ConclusionChanges in perfusion index during intraoperative EEOT in patients undergoing lung-protective ventilation (7 ml/kg) were unable to predict the response to fluid administration.© 2021. Japanese Society of Anesthesiologists.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        

    hide…