• Arch Orthop Trauma Surg · Aug 2022

    Preoperative radiographic parameters in the case of using a narrow-version femoral implant in total knee arthroplasty.

    • Jaehyun Kim, Seongyun Park, and Ji Hyun Ahn.
    • Department of Orthopedic Surgery, International Baro Hospital, Incheon, Republic of Korea.
    • Arch Orthop Trauma Surg. 2022 Aug 1; 142 (8): 2065-2074.

    BackgroundRecently, total knee arthroplasty (TKA) designs that allow the use of narrow-version femoral implants have been introduced to avoid femoral overhang. The purpose of this study was to investigate the frequency of the use of narrow-version femoral implants and identify the difference in radiographic parameters between using a narrow-version femoral implant and a standard-version femoral implant in TKA.MethodsA retrospective study was conducted on 504 primary TKAs using a TKA system (Anthem or Persona) that allowed narrow-version femoral implants. Anteroposterior (AP) dimension, mediolateral (ML) dimension, and modified aspect percentage ratio (ML/AP dimension) of the distal femur in preoperative radiographs were compared between a standard-version group (n = 275) and a narrow-version group (n = 229). A cut-off value of a modified aspect percentage ratio indicating the need for a narrow-version femoral implant was determined using the receiver operating characteristic (ROC) curve.ResultsMean ML dimension was 80.9 ± 6.1 mm in the standard-version group and 77.3 ± 4.4 mm in the narrow-version group (p < 0.001). Mean modified aspect percentage ratio was 138.8 ± 8.1% in the standard-version group and 131.7 ± 6.3% in the narrow-version group (p < 0.001). The optimum cut-off point of the modified aspect percentage ratio for narrow-version femoral implants was 135.4% (sensitivity: 72.0%; specificity: 66.7%) for Anthem and 133.3% (sensitivity: 75.9%, specificity: 76.4%) for Persona.ConclusionIn the narrow-version femoral implant group, the ML dimension and the mean modified aspect percentage ratio were smaller than in the standard-version femoral implant group. A smaller modified aspect percentage ratio of the distal femur in preoperative radiographs could predict the need for narrow-version femoral implants in TKA. It was suggested that the cut-off point could be suggested as 135.4% for Anthem TKA design and 133.3% for Persona TKA design. These radiographic parameters are cost-effective and easily applicable for planning a TKA.A smaller modified aspect percentage ratio of the distal femur in preoperative radiographs could predict the need for narrow-version femoral implants in TKA. The cut-off point was 135.4% for Anthem TKA design and 133.3% for Persona TKA design.© 2021. The Author(s), under exclusive licence to Springer-Verlag GmbH Germany, part of Springer Nature.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,694,794 articles already indexed!

We guarantee your privacy. Your email address will not be shared.