PurposeTo compare test bolus and bolus-tracking techniques for intravenous contrast material administration at 16-detector row computed tomographic (CT) coronary angiography.Materials And MethodsThis study had institutional review board approval, and patients gave informed consent. Thirty-eight patients (mean age, 60 years; three women) were randomized into two groups according to bolus timing technique: group 1 (20-mL test bolus with 100-mL main bolus) and group 2 (bolus tracking with 100-mL main bolus). All patients underwent electrocardiography-gated 16-detector row CT coronary angiography with 12 detectors (collimation, 0.75 mm; rotation time, 420 msec). In group 1, test bolus peak attenuation was used as a delay, while in group 2, a +100-HU threshold in ascending aorta triggered angiographic acquisition, with an additional 4-second delay for patient instruction. Attenuation was measured in the longitudinal direction throughout the examination in three main vessels: ascending aorta (region of interest [ROI] 1), descending aorta (ROI 2), and main pulmonary artery (ROI 3). Mean attenuation and slope of bolus geometry curve were calculated in each patient and ROI. Attenuation at origin of coronary arteries was measured. Student t test was used to compare results.ResultsMean scan delay was 6 seconds longer in group 2 (P < .05). Average attenuation values were 306.6 HU +/- 44.0 (standard deviation) and 328.2 HU +/- 58.6 (P > .05) in ROI 1, 291.6 HU +/- 45.1 and 326.4 HU +/- 62.6 (P > .05) in ROI 2, and 354.7 HU +/- 78.0 and 305.3 HU +/- 71.4 (P < .05) in ROI 3 for groups 1 and 2, respectively. Average slope values were 5.8 and -0.8 (P < .05) in ROI 1, 7.7 and 0.7 (P < .05) in ROI 2, and -1.0 and -13.3 (P < .05) in ROI 3 for groups 1 and 2, respectively. Average attenuation values in left main, left anterior descending, and left circumflex arteries were higher in group 2 (P < .05); there were no differences (P > .05) between groups in right coronary artery.ConclusionBolus-tracking yields more homogeneous enhancement than does the test bolus technique.(c) RSNA, 2004.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.