• J Invasive Cardiol · Sep 1999

    Randomized Controlled Trial Multicenter Study Comparative Study Clinical Trial

    A multicenter randomized trial comparing a percutaneous collagen hemostasis device with conventional manual compression after diagnostic angiography and angioplasty.

    • T A Sanborn, H H Gibbs, J A Brinker, W D Knopf, E J Kosinksi, and G S Roubin.
    • Cardiology Division, Department of Medicine, Starr 445, New York Hospital-Cornell Medical Center, 525 East 68 Street, New York, NY 10021, USA.
    • J Invasive Cardiol. 1999 Sep 1; 11 Suppl B: 6B-13B.

    ObjectivesA new percutaneous collagen hemostasis device was compared with conventional compression techniques after diagnostic catheterization and angioplasty. Background. Peripheral vascular complications after diagnostic catheterization or more complex interventional procedures, as well as the discomfort of manual compression and prolonged bed rest, represent significant morbidity for invasive cardiac procedures.MethodsA prospective, multicenter, randomized trial was designed to compare the hemostasis time in minutes and the incidence of vascular complications in patients receiving a vascular hemostasis device with those undergoing conventional compression techniques.ResultsAfter diagnostic catheterization, hemostasis time was significantly less with the vascular hemostasis device than with conventional manual compression (4.1 +/- 2.8 min [n=90 patients] vs. 17.6 +/- 9.2 min [n= 75], p < 0.0001). This difference was greater in patients undergoing angioplasty and was unrelated to the anticoagulation status (4.3 +/- 3.7 min [n = 71 not receiving the heparin], 7.6 +/- 11.6 min [n= 85 receiving heparin], 33.6 +/- 24.2 min [n= 134 control patients not receiving heparin], p < 0.0001 vs. control patients). The time from the start of the procedure to ambulation was slightly less after diagnostic catheterization in patients treated with the device (13.3 +/- 12.1 hours vs. 19.2 +/- 17.8 hours, p < 0.05). It was also less in patients who underwent angioplasty when the device was used after discontinuation of anticoagulation (23.0 +/- 11.1 hours, without heparin), as compared with control compression techniques (32.7 +/- 18.8 hours, p < 0.0001). Time to ambulation was even shorter (16.1 +/- 11.1 h, p < 0.0001) in patients in whom the device was placed immediately after angioplasty while they were still fully anticoagulated with a prolonged activated clotting time (336 +/- 85 s). There were no major complications (surgery or transfusion) after diagnostic catheterization and a low incidence of major complications in patients who underwent angioplasty (0.7% in control patients, 1.4% with the device without heparin, 1.2% with the device and heparin, p = NS). After angioplasty, there was a trend toward fewer hematomas when the device was used in the absence of heparin (4.2% vs. 9.7% in control patients, p = 0.14).ConclusionA new vascular hemostasis device can significantly reduce the puncture site hemostasis time and the time to ambulation without significantly increasing the risk of peripheral vascular complications The role of this technology in reducing complications, length of hospital stay and cost remains to be determined.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…