Comparative Study
Second generation intramedullary nailing of subtrochanteric femur fractures: a biomechanical study of fracture site motion.
- Craig S Roberts, Akbar Nawab, Mei Wang, Michael J Voor, and David Seligson.
- Department of Orthopaedic Surgery, University of Louisville, Louisville, Kentucky 40292, USA.
- J Orthop Trauma. 2002 Apr 1; 16 (4): 231-8.
ObjectivesTo compare fracture site motion between different second-generation intramedullary nails used to fix subtrochanteric fractures of the proximal femur with and without femoral neck fractures.DesignNondestructive mechanical testing of four types of femoral intramedullary nails was undertaken to evaluate fracture site motion using a model that simulated single-leg and double-leg stance.MethodsThree types of reconstruction nails (the Russell-Taylor Delta [Smith & Nephew, Memphis, TN], the Uniflex [Biomet, Warsaw, IN], Alta CFX [Howmedica-Osteonics, Rutherford, NJ]) and the Long Gamma nail (Howmedica-Osteonics, Rutherford, NJ), each measuring 11 x 380 mm, were inserted in fiberglass composite femurs. Four fracture patterns were studied (transverse subtrochanteric, subtrochanteric with posteromedial wedge comminution, subtrochanteric with one-centimeter gap, and a one-centimeter gap with a subcapital neck fracture). Single-and double-leg stance loading was simulated using a servohydraulic load frame (MTS, Eden Prairie, MN). Two-way analysis of variance and post hoc t tests were used to determine any statistically significant differences between groups.ResultsIn single-leg stance there were significant differences in coronal plane rotation, shear, and axial translation across the subtrochanteric fracture site between the different nail types and the different fracture patterns (p < 0.001). In double-leg stance there were significant differences in coronal plane rotation and femoral head vertical motion between the different nail types and the different fracture patterns (p < 0.001), and there were significant differences in shear and axial translation between the different fracture patterns (p < 0.001) but not the different nail types (p > 0.05).ConclusionsFor simple, well-reduced fractures the choice of implant is not critical. As fracture severity increased (comminution, gap, and combined neck fracture), the choice of implant, particularly with reference to proximal nail dimensions and implant materials, was a significant factor in reducing fracture site motion. Therefore, our laboratory data suggest that when subtrochanteric fractures are unstable (e.g., comminution, segmental bone loss) and early weight bearing is desirable, the choice of implant is critical and should be restricted to implants that allow minimal fracture site motion (Long Gamma and Russell-Taylor).
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.