Am J Infect Control · Jan 2013
Hospital-wide assessment of compliance with central venous catheter dressing recommendations.
- Mark E Rupp, Kyle Cassling, Hayley Faber, Elizabeth Lyden, Kate Tyner, Nedra Marion, and Trevor Van Schooneveld.
- Department of Internal Medicine, University of Nebraska Medical Center, Omaha, NE 68198, USA. merupp@unmc.edu
- Am J Infect Control. 2013 Jan 1; 41 (1): 89-91.
AbstractThis hospital-wide assessment of central venous catheter (CVC) site maintenance evaluated a total of 420 CVC sites and found deficiencies in 31%. Internal jugular CVC dressings were the most frequently deficient type (P = 0.001). No correlation between CVC site maintenance and central line-associated bloodstream infections was detected (Spearman's correlation coefficient = 0.007; P = 0.98).Copyright © 2013 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.