-
- Therese A Söderlund, John C Dickson, Elizabeth Prvulovich, Simona Ben-Haim, Paul Kemp, Jan Booij, Flavio Nobili, Gerda Thomsen, Osama Sabri, Pierre-Malik Koulibaly, Ozgur U Akdemir, Marco Pagani, Koen van Laere, Susanne Asenbaum-Nan, Jean George, Terez Sera, Klaus Tatsch, and Jamshed Bomanji.
- Institute of Nuclear Medicine, University College London Hospitals NHS Foundation Trust, London, United Kingdom. therese.soderlund@uclh.nhs.uk
- J. Nucl. Med. 2013 May 1;54(5):714-22.
UnlabelledClinical (123)I-2-β-carbomethoxy-3β-(4-iodophenyl)-N-(3-fluoropropyl)nortropane ((123)I-FP-CIT) SPECT studies are commonly performed and reported using visual evaluation of tracer binding, an inherently subjective method. Increased objectivity can potentially be obtained using semiquantitative analysis. In this study, we assessed whether semiquantitative analysis of (123)I-FP-CIT tracer binding created more reproducible clinical reporting. A secondary aim was to determine in what form semiquantitative data should be provided to the reporter.MethodsFifty-four patients referred for the assessment of nigrostriatal dopaminergic degeneration were scanned using SPECT/CT, followed by semiquantitative analysis calculating striatal binding ratios (SBRs) and caudate-to-putamen ratios (CPRs). Normal reference values were obtained using 131 healthy controls enrolled on a multicenter initiative backed by the European Association of Nuclear Medicine. A purely quantitative evaluation was first performed, with each striatum scored as normal or abnormal according to reference values. Three experienced nuclear medicine physicians then scored each striatum as normal or abnormal, also indicating cases perceived as difficult, using visual evaluation, visual evaluation in combination with SBR data, and visual evaluation in combination with SBR and CPR data. Intra- and interobserver agreement and agreement between observers and the purely quantitative evaluation were assessed using κ-statistics. The agreement between scan interpretation and clinical diagnosis was assessed for patients with a postscan clinical diagnosis available (n = 35).ResultsThe physicians showed consistent reporting, with a good intraobserver agreement obtained for the visual interpretation (mean κ ± SD, 0.95 ± 0.029). Although visual interpretation of tracer binding gave good interobserver agreement (0.80 ± 0.045), this was improved as SBRs (0.86 ± 0.070) and CPRs (0.95 ± 0.040) were provided. The number of striata perceived as difficult to interpret decreased as semiquantitative data were provided (30 for the visual interpretation; 0 as SBR and CPR values were given). The agreement between physicians' interpretations and the purely quantitative evaluation showed that readers used the semiquantitative data to different extents, with a more experienced reader relying less on the semiquantitative data. Good agreement between scan interpretation and clinical diagnosis was seen.ConclusionA combined approach of visual assessment and semiquantitative analysis of tracer binding created more reproducible clinical reporting of (123)I-FP-CIT SPECT studies. Physicians should have access to both SBR and CPR data to minimize interobserver variability.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.