• Critical care medicine · Jul 2000

    Effects of guidelines implementation in a surgical intensive care unit to control nighttime light and noise levels.

    • B Walder, D Francioli, J J Meyer, M Lançon, and J A Romand.
    • Department APSIC, Geneva University Hospital, Switzerland.
    • Crit. Care Med. 2000 Jul 1;28(7):2242-7.

    ObjectiveBecause of around-the-clock activities, environmental noise and light are among the many causes of sleep disturbance in an intensive care unit (ICU). The implementation of guidelines may potentially change behavior rules and improve sleep quality.DesignA prospective interventional study, observing the effects of simple nighttime guidelines on light and noise levels in an ICU.SettingA modern surgical ICU, subdivided into six identical three-bed rooms.PatientsCritically ill adult patients.InterventionBetween two observation periods, five guidelines were implemented to decrease both light and noise during the night shift in the patient's room.MeasurementLight levels and noise levels were obtained using a luxmeter and a sound level meter [A-weighted decibels (dB) scale] and were monitored continuously from 11 pm to 5 am both before (period P1) and after (period P2) the implementation of guidelines.Main ResultsSimilar patient's gravity and nursing workload scores were observed between P1 and P2. A low mean (<5 Lux) and maximal light level were measured during both P1 and P2. The implementation of guidelines lowered mean light disturbance intensity with a greater variability of light during P2. All noise levels were high and corresponded more to a quiet office for noise level equivalents and to a busy restaurant for peak noise levels during both P1 and P2. Guidelines decreased the noise level equivalent (P1, 51.3 dB; P2, 48.3 dB), peak noise level (P1, 74.9 dB; P2, 70.8 dB), and the number of acoustic identified alarms (P1, 22.1 dB; P2, 15.8 dB) during P2.ConclusionThe night light levels were low during both periods, and lowering the light levels induced a greater variation of light, which may impair sleep quality. All measured noise levels were high during both periods, which could contribute to sleep disturbance, and the implementation of guidelines significantly lowers some important noise levels. The background noise level was unchanged.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.