- Russell J Miller, Lakshmi Mudambi, Macarena R Vial, Mike Hernandez, and George A Eapen.
- 1 Department of Pulmonary Medicine and.
- Ann Am Thorac Soc. 2017 Jul 1; 14 (7): 1162-1168.
RationaleEndobronchial ultrasound (EBUS) has transformed mediastinal staging in lung cancer. A systematic approach, beginning with lymph nodes contralateral to the primary tumor (N3), is considered superior to selective sampling of radiographically abnormal nodes. However, the extent to which this recommendation is followed in practice remains unknown.ObjectivesTo assess the frequency with which pulmonologists, pulmonary fellows, and interventional pulmonologists endoscopically stage lung cancer appropriately.MethodsBronchoscopists currently performing EBUS were surveyed about their practice patterns, procedural volume, and self-confidence in EBUS skills; they then performed a proctored simulated staging EBUS. The primary outcome was the proportion of participants who appropriately initiated ultrasonographic evaluation with the N3 nodal stations in a simulated patient undergoing EBUS for mediastinal staging.ResultsSixty physicians (22 interventional pulmonologists, 18 general pulmonologists, and 20 pulmonary fellows) participated in the study. The rates of appropriate staging by study group were 95.5% (21 of 22) for interventional pulmonologists, 44.4% (8 of 18) for general pulmonologists, and 30.0% (6 of 20) for pulmonary fellows (P < 0.001). Increased procedural volume correlated with appropriate staging practices (P < 0.001). Within each group, we assessed the concordance between self-confidence in EBUS and simulation performance. Among interventional pulmonologists, the concordance was 95.4%, followed by 61.1% for general pulmonologists and 40.0% for pulmonary fellows.ConclusionsGeneral pulmonologists and pulmonary fellows were less likely than interventional pulmonologists to perform appropriate EBUS staging. In addition, the lack of concordance between self-confidence and appropriate staging performance among noninterventionists signals a need for improved dissemination of guidelines for EBUS-guided mediastinal staging.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.