• Interact Cardiovasc Thorac Surg · Dec 2012

    Review

    Is totally endoscopic coronary artery bypass safe, feasible and effective?

    • Metesh Nalin Acharya, Hutan Ashrafian, Thanos Athanasiou, and Roberto Casula.
    • Department of Cardiothoracic Surgery, Imperial College London, Hammersmith Hospital Campus, London, UK.
    • Interact Cardiovasc Thorac Surg. 2012 Dec 1;15(6):1040-6.

    AbstractA best evidence topic was written according to a structured protocol. The question addressed was whether totally endoscopic coronary artery bypass (TECAB) is safe, effective and feasible. A total of 171 papers were found, of which eight represented the best evidence. The authors, date, journal, study type, population, main outcome measures and results are tabulated. The da Vinci robotic system was utilized in seven retrospective studies and one multicentre prospective trial, comprising 724 patients undergoing TECAB. Patient-related outcomes, including the incidence of major adverse cardiac events, graft patency and survival, were investigated. From the studies evaluated, TECAB appears to be safe operation with low complication rates and excellent early- and mid-term graft patencies. The incidence of internal thoracic artery injury was documented in four studies and ranged from 0 to 10%. Re-exploration for bleeding was necessary in 1-15% of patients. Conversion to open techniques was performed in 0-24% of cases. There was no in-hospital mortality in the majority of studies, but this reached 2.1% in a large series of 228 patients. Target-vessel reintervention rates varied between 0 and 12.1% according to the institutional experience. Pre- and post-discharge graft patencies were excellent at 93-100 and 92-100%, respectively. Intraoperative variables, such as time taken for internal thoracic artery harvest, anastomosis, cross-clamp, cardiopulmonary bypass (CPB) and the overall operation were as follows: internal thoracic artery harvest time (range 5-187 min), anastomosis time (range 6-82 min), cross-clamp time (range 30-223 min), CPB time (range 41-268 min) and operative time (range 84-600 min). TECAB is a technically demanding and time-consuming procedure associated with a significant learning curve. Proctoring and structured training programmes are currently supported by European and international societies to encourage wider uptake of the procedure. In conclusion, TECAB represents a feasible alternative to conventional coronary artery bypass in selected patients. It is associated with low morbidity and excellent mid-term graft patency. Larger, prospective and multicentre trials are required to assess the long-term and patient-reported outcomes of TECAB.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…