-
Eur J Phys Rehabil Med · Feb 2015
Randomized Controlled TrialPursed lip breathing improves exercise tolerance in COPD: a randomized crossover study.
- L Ferracini Cabral, T Da Cunha D'Elia, D De Sousa Marins, W Araujo Zin, and F Silva Guimarães.
- Physical Therapy School, Federal University of Juiz de Fora, Juiz de Fora, Brazil - fguimaraes_pg@yahoo.com.br.
- Eur J Phys Rehabil Med. 2015 Feb 1; 51 (1): 79-88.
BackgroundAlthough pursed-lip breathing (PLB) has been advocated to reduce respiratory rate and improve oxygen saturation in patients with chronic obstructive pulmonary disease (COPD) at rest, the evidence of its effects on dynamic hyperinflation (DH) and exercise tolerance is scarce.AimTo evaluate the effect of PLB on exercise tolerance, breathing pattern, dynamic hyperinflation and arterial oxygenation in COPD patients during high-intensity exercise.DesignRandomized crossover study.SettingLaboratory of Respiration Physiology, Federal University of Rio de Janeiro.PopulationForty stable COPD patients aged 40-75 years and with FEV1<60%.MethodsIn a randomized order, all patients performed PLB and control breathing (CB) during constant work-rate exercise in an electrically-braked cycloergometer. Dynamic hyperinflation, oxygen saturation and breathing pattern were recorded at rest, in isotime and in peak exercise.ResultsThe nine patients who increased their endurance time by more than 25% during PLB (6.42 ± 2.36 vs. 10.51 ± 3.83 min; P < 0.05) were considered as the Improver sub-group. Compared to the Non-improver subgroup, these patients presented a lower expiratory peak flow - EPF (40.2 ± 8.6 vs. 53.3 ± 17.8 % predicted, P<0.05). The ROC Curve analysis of the EPF as a percentage of the predicted values (%pred) was performed to identify cut-off values that had greater sensitivity and specificity in differentiating between IMPROVER and NON-IMPROVER. We observed 61% sensitivity and 89% specificity with a 47.7% pred EPF. At isotime, PLB yielded higher inspiratory capacity (IC) and oxygen saturation (1.19 ± 0.33 to 1.35 ± 0.39 L; P < 0.05 and 93.1 ± 4.6 to 94.0 ± 4.1%; P<0.05), and lower respiratory rate than CB only in Improver. Non-improver patients showed thoracoabdominal asynchrony during PLB in isotime. At peak exercise, PLB improved the arterial oxygenation in Improver, but there were no changes in the breathing pattern in the analyzed subgroups.ConclusionIn COPD patients with low PEF, pursed-lip breathing reduces dynamic hyperinflation and improves exercise tolerance, breathing pattern and arterial oxygenation at submaximal intensity exercise.Clinical Rehabilitation ImpactThis study points to a possible application of PLB in a selected group of COPD patients aiming at improving the exercise tolerance. PEF measurements can help to indicate PLB for COPD patients.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.