Observational Study
The effect of patient ethnicity on the accuracy of peripheral pulse oximetry in patients with COVID-19 pneumonitis: a single-centre, retrospective analysis.
- M D Wiles, A El-Nayal, G Elton, M Malaj, J Winterbottom, C Gillies, I K Moppett, and K Bauchmuller.
- Department of Critical Care, Sheffield Teaching Hospitals NHS Foundation Trust, Sheffield, UK.
- Anaesthesia. 2022 Feb 1; 77 (2): 143-152.
AbstractPulse oximetry is used widely to titrate oxygen therapy and for triage in patients who are critically ill. However, there are concerns regarding the accuracy of pulse oximetry in patients with COVID-19 pneumonitis and in patients who have a greater degree of skin pigmentation. We aimed to determine the impact of patient ethnicity on the accuracy of peripheral pulse oximetry in patients who were critically ill with COVID-19 pneumonitis by conducting a retrospective observational study comparing paired measurements of arterial oxygen saturation measured by co-oximetry on arterial blood gas analysis (SaO2 ) and the corresponding peripheral oxygenation saturation measured by pulse oximetry (Sp O2 ). Bias was calculated as the mean difference between SaO2 and Sp O2 measurements and limits of agreement were calculated as bias ±1.96 SD. Data from 194 patients (135 White ethnic origin, 34 Asian ethnic origin, 19 Black ethnic origin and 6 other ethnic origin) were analysed consisting of 6216 paired SaO2 and Sp O2 measurements. Bias (limits of agreement) between SaO2 and Sp O2 measurements was 0.05% (-2.21-2.30). Patient ethnicity did not alter this to a clinically significant degree: 0.28% (1.79-2.35), -0.33% (-2.47-2.35) and -0.75% (-3.47-1.97) for patients of White, Asian and Black ethnic origin, respectively. In patients with COVID-19 pneumonitis, Sp O2 measurements showed a level of agreement with SaO2 values that was in line with previous work, and this was not affected by patient ethnicity.© 2021 Association of Anaesthetists.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.