-
Frontiers in neuroscience · Jan 2021
The Relationships Among Transverse Sinus Stenosis Measured by CT Venography, Venous Trans-stenotic Pressure Gradient and Intracranial Pressure in Patients With Unilateral Venous Pulsatile Tinnitus.
- Xiaoyu Qiu, Pengfei Zhao, Xiaoshuai Li, Heyu Ding, Han Lv, Rong Zeng, Guopeng Wang, Long Jin, Zhenghan Yang, Shusheng Gong, and Zhenchang Wang.
- Department of Radiology, Beijing Friendship Hospital, Capital Medical University, Beijing, China.
- Front Neurosci. 2021 Jan 1; 15: 694731.
ObjectivesTo assess a non-invasive means of predicting a venous trans-stenotic pressure gradient (TPG) and intracranial pressure (ICP) as opposed to invasive examinations in unilateral venous pulsatile tinnitus (PT) patients.MethodsThirty patients with unilateral venous PT who presented symptomatic-sided transverse sinus stenosis (TSS) on computed tomography venography (CTV), ipsilateral TPG measured by digital subtraction angiography (DSA) and cerebrospinal fluid (CSF) pressure measured by lumbar puncture were included. The ratio of TSS was calculated by dividing the cross-sectional areas of the maximal stenosed transverse sinus by that of the adjacent normal transverse sinus on CTV. The correlations among and predictive values of TSS, TPG, and ICP were analyzed.ResultsIn patients with unilateral venous PT, the symptomatic-sided and average bilateral TSS values were 78 ± 11 and 77 ± 9%; ICP, 230.50 ± 55.75 mmH2O; and the TPG, 9.51 ± 5.76 mmHg. The symptomatic-sided TSS was linearly and positively correlated with TPG (R 2 = 0.400), and the symptomatic-sided and bilateral average TSS both showed weak correlations with ICP (R 2 = 0.288, R'2 = 0.156). When the degree of TSS increased by 10%, the TPG and ICP increased by approximately 3.3 mmHg and 25.8 mmH2O, respectively. The receiver operating characteristic curve showed the optimal threshold of ipsilateral TSS for a positive TPG was 0.75, while TSS had no significant predictive value for ICP (p > 0.05). TPG and ICP also exhibited a linear positive correlation (R 2 = 0.552). When ICP increased by 10 mmH2O, the TPG increased by approximately 0.77 mmHg, and the optimal threshold of ICP for a positive TPG was 227.5.ConclusionTSS, TPG, and ICP are interrelated. TSS measured by CTV can predict TPG in patients with unilateral venous PT.Copyright © 2021 Qiu, Zhao, Li, Ding, Lv, Zeng, Wang, Jin, Yang, Gong and Wang.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.