- Remco J P Doodkorte, Alex K Roth, Eva Jacobs, Jacobus J C Arts, and Paul C Willems.
- Department of Orthopaedic Surgery, Research School CAPHRI, Maastricht University Medical Center, P. Debyelaan 25, 6229 HX, Maastricht, the Netherlands.
- Spine. 2022 May 1; 47 (9): E415E422E415-E422.
Study DesignA porcine cadaveric biomechanical study.ObjectiveTo biomechanically evaluate a novel Cable Anchor System as semi-rigid junctional fixation technique for the prevention of proximal junctional failure after adult spinal deformity surgery and to make a comparison to alternative promising prophylactic techniques.Summary Of Background DataThe abrupt change of stiffness at the proximal end of a pedicle screw construct is a major risk factor for the development of proximal junctional failure after adult spinal deformity surgery. A number of techniques that aim to provide a gradual transition zone in range of motion (ROM) at the proximal junction have previously been studied. In this study, the design of a novel Cable Anchor System, which comprises a polyethylene cable for rod fixation, is assessed.MethodsTen T6-T13 porcine spine segments were subjected to cyclic 4 Nm pure-moment loading. The following conditions were tested: uninstrumented, 3 level pedicle screw fixation (PSF), and PSF with supplementary Cable Anchors applied proximally at 1-level (Anchor1) or 2-levels (Anchor2), transverse process hooks (TPH), and 2-level sublaminar tapes (Tape2). The normalized segmental range of motion in the junctional zone was compared using one-way analysis of variance and linear regression.ResultsStatistical comparison at the level proximal to PSF showed significantly lower ROMs for all techniques compared to PSF fixation alone in all movement directions. Linear regression demonstrated a higher linearity for Anchor1 (0.820) and Anchor2 (0.923) in the junctional zone in comparison to PSF (1-level: 0.529 and 2-level: 0.421). This linearity was similar to the compared techniques (TPH and Tape2).ConclusionThe Cable Anchor System presented in this study demonstrated a gradual ROM transition zone at the proximal end of a rigid pedicle screw construct similar to TPH and 2-level sublaminar tape semi-rigid junctional fixation constructs, while providing the benefit of preserving the posterior ligament complex.Level of Evidence: 5.Copyright © 2021 Wolters Kluwer Health, Inc. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.