• Circulation · Apr 2017

    Impact of Practice-Based Management of Pulmonary Artery Pressures in 2000 Patients Implanted With the CardioMEMS Sensor.

    • J Thomas Heywood, Rita Jermyn, David Shavelle, William T Abraham, Arvind Bhimaraj, Kunjan Bhatt, Fareed Sheikh, Eric Eichorn, Sumant Lamba, Rupinder Bharmi, Rahul Agarwal, Charisma Kumar, and Lynne W Stevenson.
    • From the Division of Cardiology, Scripps Clinic Torrey Pines, La Jolla, CA (J.T.H.); St. Francis Hospital, Roslyn, NY (R.J.); Division of Cardiovascular Medicine, Keck School of Medicine, Los Angeles, CA (D.S.); The Ohio State University, Columbus (W.T.A.); Houston Methodist Hospital, TX (A.B.); Austin Heart Hospital, Austin, TX (K.B.); St. Rose Dominican Hospital, Las Vegas, NV (F.S.); Medical City of Dallas, TX (E.E.); First Coast Cardiovascular Institute, Jacksonville, FL (S.L.); Clinical Research and Development, St. Jude Medical, Inc, Sylmar, CA (R.B., R.A., C.K.); and Division of Cardiovascular Medicine, Brigham and Women's Hospital, Boston, MA (L.W.S.). heywood.james@scrippshealth.org.
    • Circulation. 2017 Apr 18; 135 (16): 1509-1517.

    BackgroundElevated pulmonary artery (PA) pressures in patients with heart failure are associated with a high risk for hospitalization and mortality. Recent clinical trial evidence demonstrated a direct relationship between lowering remotely monitored PA pressures and heart failure hospitalization risk reduction with a novel implantable PA pressure monitoring system (CardioMEMS HF System, St. Jude Medical). This study examines PA pressure changes in the first 2000 US patients implanted in general practice use.MethodsDeidentified data from the remote monitoring Merlin.net (St. Jude Medical) database were used to examine PA pressure trends from the first consecutive 2000 patients with at least 6 months of follow-up. Changes in PA pressures were evaluated with an area under the curve methodology to estimate the total sum increase or decrease in pressures (mm Hg-day) during the follow-up period relative to the baseline pressure. As a reference, the PA pressure trends were compared with the historic CHAMPION clinical trial (CardioMEMS Heart Sensor Allows Monitoring of Pressure to Improve Outcomes in New York Heart Association [NYHA] Functional Class III Heart Failure Patients). The area under the curve results are presented as mean±2 SE, and P values comparing the area under the curve of the general-use cohort with outcomes in the CHAMPION trial were computed by the t test with equal variance.ResultsPatients were on average 70±12 years old; 60% were male; 34% had preserved ejection fraction; and patients were followed up for an average of 333±125 days. At implantation, the mean PA pressure for the general-use patients was 34.9±10.2 mm Hg compared with 31.3±10.9 mm Hg for CHAMPION treatment and 32.0±10.5 mm Hg for CHAMPION control groups. The general-use patients had an area under the curve of -32.8 mm Hg-day at the 1-month time mark, -156.2 mm Hg-day at the 3-month time mark, and -434.0 mm Hg-day after 6 months of hemodynamic guided care, which was significantly lower than the treatment group in the CHAMPION trial. Patients consistently transmitted pressure information with a median of 1.27 days between transmissions after 6 months.ConclusionsThe first 2000 general-use patients managed with hemodynamic-guided heart failure care had higher PA pressures at baseline and experienced greater reduction in PA pressure over time compared with the pivotal CHAMPION clinical trial. These data demonstrate that general use of implantable hemodynamic technology in a nontrial setting leads to significant lowering of PA pressures.© 2017 American Heart Association, Inc.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…