• J Chin Med Assoc · Nov 2021

    Biomechanical comparisons of different diagonal screw designs in a novel embedded calcaneal slide plate.

    • Shun-Ping Wang, Wei-Yi Lai, Yi-Yin Lin, Tzu-Wei Lin, Ming-Tzu Tsai, Yi-Ping Yang, Cheng-En Hsu, Chao-Ping Chen, Cheng-Hung Lee, and Kuo-Chih Su.
    • Department of Orthopedics, Taichung Veterans General Hospital, Taichung, Taiwan, ROC.
    • J Chin Med Assoc. 2021 Nov 1; 84 (11): 103810471038-1047.

    BackgroundMedial displacement calcaneal osteotomy (MDCO) is frequently used for the surgical correction of flatfoot. This study aims to investigate the biomechanical effect of the different diagonal screw design on a novel-designed embedded calcaneal plate for MDCO using finite element analysis (FEA), mechanical test and digital image correlation (DIC) measurement.MethodsFour groups according to the varied implanted plate were set as control group (Group 1), non-diagonal screw (Group 2), one-diagonal screw (Group 3), and two-diagonal screws groups (Group 4). For FEA, A 450 N load was applied to on the anterior process of the calcaneus from top to bottom. Observational indices included the stress on the cortical and cancellous bone of the calcaneus surrounding the implant, the plate itself as well as screws, and the displacement of the overall structure. In addition, this study also used in vitro biomechanics test to investigate the stiffness of the structure after implantation, and used DIC to observe the displacement of the calcaneus structure after external force.ResultsUnder a simulated load in FEA, there are significant overall instability and high stress concentration on the calcaneal surrounding host bone and the plate/screws system, respectively, in group 2 compared with other groups. Regard to the mechanical testing with DIC system, significant increased rotation stability, maximum force and stiffness with the addition of diagonal screws. In comparison to Group 2, the increase of 112% and 157% in maximum force as well as 104% and 176% in stiffness were found in Group 3 and 4, respectively.ConclusionFor reducing stress concentration and enhancing overall stability, more than one-diagonal screw design is recommended and two-diagonal screws design will be superior. This study provided biomechanical references for further calcaneal implants design to prevent clinical failure after MDCO.Copyright © 2021, the Chinese Medical Association.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…