- Kirk C McGilvray, Erik I Waldorff, Jeremiah Easley, Howard B Seim, Nianli Zhang, Raymond J Linovitz, James T Ryaby, and Christian M Puttlitz.
- Orthopaedic Bioengineering Research Laboratory, Department of Mechanical Engineering, Colorado State University, 1374 Campus Delivery, Fort Collins, CO 80523, USA. Electronic address: kirkmcgilvray@gmail.com.
- Spine J. 2017 Dec 1; 17 (12): 1907-1916.
Background ContextThe most commonly used materials used for interbody cages are titanium metal and polymer polyetheretherketone (PEEK). Both of these materials have demonstrated good biocompatibility. A major disadvantage associated with solid titanium cages is their radiopacity, limiting the postoperative monitoring of spinal fusion via standard imaging modalities. However, PEEK is radiolucent, allowing for a temporal assessment of the fusion mass by clinicians. On the other hand, PEEK is hydrophobic, which can limit bony ingrowth. Although both PEEK and titanium have demonstrated clinical success in obtaining a solid spinal fusion, innovations are being developed to improve fusion rates and to create stronger constructs using hybrid additive manufacturing approaches by incorporating both materials into a single interbody device.PurposeThe purpose of this study was to examine the interbody fusion characteristic of a PEEK Titanium Composite (PTC) cage for use in lumbar fusion.Study Design/SettingThirty-four mature female sheep underwent two-level (L2-L3 and L4-L5) interbody fusion using either a PEEK or a PTC cage (one of each per animal). Animals were sacrificed at 0, 8, 12, and 18 weeks post surgery.Materials And MethodsPost sacrifice, each surgically treated functional spinal unit underwent non-destructive kinematic testing, microcomputed tomography scanning, and histomorphometric analyses.ResultsRelative to the standard PEEK cages, the PTC constructs demonstrated significant reductions in ranges of motion and a significant increase in stiffness. These biomechanical findings were reinforced by the presence of significantly more bone at the fusion site as well as ingrowth into the porous end plates.ConclusionsOverall, the results indicate that PTC interbody devices could potentially lead to a more robust intervertebral fusion relative to a standard PEEK device in a clinical setting.Copyright © 2017 The Author(s). Published by Elsevier Inc. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.