• Am. J. Respir. Crit. Care Med. · Jun 2006

    Comparative Study

    Bronchoscopy in ventilator-associated pneumonia: agreement of calibrated loop and serial dilution.

    • Bekele Afessa, Rolf D Hubmayr, Emily A Vetter, Mark T Keegan, Karen L Swanson, Larry M Baddour, Franklin R Cockerill, and Steve G Peters.
    • Division of Pulmonary and Critical Care Medicine, Department of Medicine, Mayo Clinic College of Medicine, Rochester, MN 55905, USA. afessa.bekele@mayo.edu
    • Am. J. Respir. Crit. Care Med. 2006 Jun 1; 173 (11): 1229-32.

    RationaleAlthough the serial dilution technique for quantitative culture of bronchoalveolar fluid is considered to be the gold standard for the diagnosis of ventilator-associated pneumonia, it is more labor intensive than the calibrated loop technique.ObjectiveWe sought to determine the agreement between the calibrated loop and serial dilution techniques in the diagnosis of ventilator-associated pneumonia.MethodsWe prospectively measured bacterial colony counts by the serial dilution and calibrated loop techniques in 121 bronchoalveolar lavage samples of 104 patients with suspected ventilator-associated pneumonia.Measurements And Main ResultsAt the time of bronchoscopy, patients had received mechanical ventilation for a median of 8 d. Patients were receiving antibiotics when 90 of the 121 (74.4%) bronchoalveolar samples were obtained. The colony counts of 13 bacterial isolates were too numerous to count by the calibrated loop technique; by serial dilution technique, their counts ranged from 4.70 to 6.74 log10 cfu/ml. Fifty other bacteria had paired colony counts measured by each of the two techniques: the bias (95% confidence interval) between the two techniques was -0.380 (-0.665 to -0.095) log10 cfu/ml, with precision of 1.002 log10 cfu/ml and 95% limits of agreement of -2.344 to 1.584 log10 cfu/ml. Using the threshold of 4 log10 cfu/ml as a criterion for the diagnosis of ventilator-associated pneumonia, there was discordance only for one bacterial organism between the two techniques.ConclusionsThe calibrated loop technique can be used for the diagnosis of ventilator-associated pneumonia using bronchoalveolar lavage fluid.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,704,841 articles already indexed!

We guarantee your privacy. Your email address will not be shared.