Comparative StudyBronchoscopy in ventilator-associated pneumonia: agreement of calibrated loop and serial dilution.
- Bekele Afessa, Rolf D Hubmayr, Emily A Vetter, Mark T Keegan, Karen L Swanson, Larry M Baddour, Franklin R Cockerill, and Steve G Peters.
- Division of Pulmonary and Critical Care Medicine, Department of Medicine, Mayo Clinic College of Medicine, Rochester, MN 55905, USA. afessa.bekele@mayo.edu
- Am. J. Respir. Crit. Care Med. 2006 Jun 1; 173 (11): 1229-32.
RationaleAlthough the serial dilution technique for quantitative culture of bronchoalveolar fluid is considered to be the gold standard for the diagnosis of ventilator-associated pneumonia, it is more labor intensive than the calibrated loop technique.ObjectiveWe sought to determine the agreement between the calibrated loop and serial dilution techniques in the diagnosis of ventilator-associated pneumonia.MethodsWe prospectively measured bacterial colony counts by the serial dilution and calibrated loop techniques in 121 bronchoalveolar lavage samples of 104 patients with suspected ventilator-associated pneumonia.Measurements And Main ResultsAt the time of bronchoscopy, patients had received mechanical ventilation for a median of 8 d. Patients were receiving antibiotics when 90 of the 121 (74.4%) bronchoalveolar samples were obtained. The colony counts of 13 bacterial isolates were too numerous to count by the calibrated loop technique; by serial dilution technique, their counts ranged from 4.70 to 6.74 log10 cfu/ml. Fifty other bacteria had paired colony counts measured by each of the two techniques: the bias (95% confidence interval) between the two techniques was -0.380 (-0.665 to -0.095) log10 cfu/ml, with precision of 1.002 log10 cfu/ml and 95% limits of agreement of -2.344 to 1.584 log10 cfu/ml. Using the threshold of 4 log10 cfu/ml as a criterion for the diagnosis of ventilator-associated pneumonia, there was discordance only for one bacterial organism between the two techniques.ConclusionsThe calibrated loop technique can be used for the diagnosis of ventilator-associated pneumonia using bronchoalveolar lavage fluid.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:

- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.