• Anesthesia and analgesia · Sep 1999

    Randomized Controlled Trial Clinical Trial

    Fentanyl pretreatment does not impair the reliability of an epinephrine-containing test dose during propofol-nitrous oxide anesthesia.

    • S Takahashi, M Tanaka, and H Toyooka.
    • Department of Anesthesia, Institute of Clinical Medicine, University of Tsukuba, Ibaraki, Japan.
    • Anesth. Analg. 1999 Sep 1;89(3):743-7.

    UnlabelledWe designed this study to determine the hemodynamic responses to and the efficacy of a simulated IV test dose during propofol anesthesia based on the conventional heart rate (HR; positive if increase > or =20 bpm), the modified HR (positive if increase > or =10 bpm), and the systolic blood pressure (SBP; positive if increase > or =15 mm Hg) criteria. Eighty healthy patients were randomized to receive 2 mg/kgpropofol or propofol plus fentanyl (100 microg) at the induction of anesthesia (n = 40 each). After endotracheal intubation, anesthesia in both groups was maintained with propofol 8 mg x kg(-1) x h(-1) and 67% nitrous oxide in oxygen. Each group of patients was further divided into a test dose group receiving 1.5% lidocaine 3 mL plus epinephrine 15 microg (1:200,000) or a saline group (n = 20 each) receiving 3 mL of isotonic sodium chloride solution i.v. HR and SBP were monitored for 4 min after the i.v. injection of the study drug. The i.v. injection of the test dose produced a HR increase > or =20 bpm in 20 and 17 patients in the propofol and propofol-fentanyl groups, respectively, whereas all patients receiving the test dose and none receiving saline had HR increases > or =10 bpm. Therefore, in the propofol-fentanyl group, sensitivity, specificity, positive predictive value, and negative predictive value were 85%, 100%, 100%, and 87% according to the conventional HR criterion, and all were 100% according to the modified HR criterion. In the propofol group, 100% efficacy was obtained based on both HR criteria. However, all patients receiving the test dose and none receiving saline developed a SBP increase > or =15 mm Hg, resulting in 100% efficacy based on the conventional SBP criterion in both groups. Our results indicate that both the modified HR criterion and the SBP criterion are clinically applicable during propofol anesthesia with or without supplemental fentanyl.ImplicationsTo determine whether an epidural catheter is in a blood vessel, an epidural test dose containing 15 microg of epinephrine is used. We found that, during propofol anesthesia with or without fentanyl, a heart rate increase > or =10 bpm and a systolic blood pressure increase > or =15 mm Hg are reliable indicators for detecting accidental intravascular injection.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,694,794 articles already indexed!

We guarantee your privacy. Your email address will not be shared.