• J Clin Apher · Aug 2019

    Comparative Study Clinical Trial

    Mononuclear cell collection for extracorporeal photopheresis by using the "off-line" system: A comparative study between COBE Spectra and Spectra Optia devices.

    • Cristina Pascual, Elena González-Arias, Ana María Pérez-Corral, Rebeca Bailén, Jorge Gayoso, Nelly Besson, David Serrano, Mi Kwon, Javier Anguita, and José Luis Díez-Martín.
    • Hemathology and Hemotherapy Department, Hospital General Universitario Gregorio Marañón, Madrid, Spain.
    • J Clin Apher. 2019 Aug 1; 34 (4): 359-366.

    BackgroundExtracorporeal photopheresis (ECP) is an efficient and established therapy to treat acute and chronic graft vs host disease (GVHD). Using an "off-line" method, the first step (mononuclear cell [MNC] collection) is decisive, as long as a high MNC yield and purity in the collected product is desirable. Two "off-line" devices were compared: the COBE Spectra and the Spectra Optia (Terumo BCT), using both continuous and intermittent protocols.Patients And MethodsTwelve patients with GvHD (7 acute/5 chronic) were enrolled between June 2014 and May 2015 and were alternatively assigned for each procedure to either the COBE Spectra or the Spectra Optia cell separator. Patients characteristics and procedure/product parameters were analyzed.ResultsTwo hundred procedures (100 per device) were included. The Spectra Optia system showed higher total nucleated cells and MNC collection efficiencies (18.6(10.2-29.7) vs 7.9(4.1-14.8)% and 43.6(20.3-59.5) vs 23.3(11.4-37.1)%, P < .001) and monocyte and lymphocyte collection efficiencies (55.2(17.7-83.2) vs 22.8(9-38.9)% and 38.3(26.7-53.4) vs 22.2(9-38.9)%, respectively, P < .001). Absolute platelet loss (PL) and PL per liter of blood processed were significantly lower in the Spectra Optia group (22.9(18.3-28.1) vs 33.6(26.5-41.1)%, P < .001 and 3.7(3.1-4.5) vs 4.3(3.5-4.2)%, P = .01, respectively). However, granulocyte contamination was higher (4.5(1.3-36) vs 1.2(0.4-5.7)%, P < .001) and a higher product haematocrit was obtained with the Spectra Optia (1(0.5-1.6) vs 0.3(0.2-0.5)%, P < .001), without an impact on irradiation time.ConclusionsIn our study, Spectra Optia proved to be safe and effective in collecting MNC with high yield and purity for ECP in GvHD.© 2018 Wiley Periodicals, Inc.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.