• Acad Emerg Med · Feb 2008

    Correlation of optic nerve sheath diameter with direct measurement of intracranial pressure.

    • Heidi Harbison Kimberly, Sachita Shah, Keith Marill, and Vicki Noble.
    • Department of Emergency Medicine, Massachusetts General Hospital, Boston, MA, USA. hkimberly@partners.org
    • Acad Emerg Med. 2008 Feb 1;15(2):201-4.

    BackgroundMeasurements of the optic nerve sheath diameter (ONSD) using bedside ultrasound (US) have been shown to correlate with clinical and radiologic signs and symptoms of increased intracranial pressure (ICP).ObjectivesPrevious literature has identified 5 mm as the ONSD measurement above which patients exhibit either clinical or radiologic signs of elevated ICP. The goals of this study were to evaluate the association between ONSD and ICP and to validate the commonly used ONSD threshold of 5 mm using direct measurements of ICP as measured by ventriculostomy.MethodsA prospective blinded observational study was performed using a convenience sample of adult patients in both the emergency department (ED) and the neurologic intensive care unit (ICU) who had invasive intracranial monitors placed as part of their clinical care. Ocular USs were performed with a 10(-5) MHz linear probe. Emergency physicians (EPs) with previous ocular US experience performed ONSD measurements while blinded to the contemporaneous ICP reading obtained directly from invasive monitoring. The association between ONSD and ICP was assessed with the Spearman rank correlation coefficient, and a receiver operator characteristic (ROC) curve was created to determine the optimal ONSD cutoff to detect ICP > 20 cm H2O.ResultsThirty-eight ocular USs were performed on 15 individual patients. Spearman rank correlation coefficient of ONSD and ICP was 0.59 (p < 0.0005) demonstrating a significant positive correlation. An ROC curve was created to assess the ability of ONSD to distinguish an abnormal ICP greater than 20 cm H2O. The area under the ROC curve was 0.93 (95% confidence interval [CI] = 0.84 to 0.99). Based on inspection of the ROC curve, ONSD > 5 mm performed well to detect ICP > 20 cm H(2)O with a sensitivity of 88% (95% CI = 47% to 99%) and specificity of 93% (95% CI = 78% to 99%).ConclusionsUsing an ROC curve the authors systematically confirmed the commonly used threshold of ONSD > 5 mm to detect ICP > 20 cm H2O. This study directly correlates ventriculostomy measurements of ICP with US ONSD measurements and provides further support for the use of ONSD measurements as a noninvasive test for elevated ICP.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…