Eur J Trauma Emerg Surg · Oct 2022
3D virtual pre-operative planning may reduce the incidence of dorsal screw penetration in volar plating of intra-articular distal radius fractures.
- Jasper Prijs, Bram Schoolmeesters, Denise Eygendaal, de VriesJean-Paul P MJPMDepartment of Surgery, University of Groningen, University Medical Center Groningen, BA13, Hanzeplein 1, 9713 GZ, Groningen, The Netherlands., Paul C Jutte, Job N Doornberg, Ruurd L Jaarsma, IJpmaFrank F AFFADepartment of Surgery, University of Groningen, University Medical Center Groningen, BA13, Hanzeplein 1, 9713 GZ, Groningen, The Netherlands., and Traumaplatform 3D Consortium.
- Department of Orthopaedic and Trauma Surgery, Flinders University and Flinders Medical Centre, Adelaide, Australia. j.prijs@umcg.nl.
- Eur J Trauma Emerg Surg. 2022 Oct 1; 48 (5): 3911-3921.
PurposeTo evaluate the effect of three-dimensional virtual pre-operative planning (3DVP) on the incidence of dorsal screw penetration after volar plating of distal radius fractures.MethodsA cross-sectional diagnostic imaging study was performed. Twenty out of 50 patients were randomly selected from our index prospective cohort (IPC): a prior study evaluating dorsal tangential views (DTVs) in reducing dorsal screw penetration in internal fixation of intra-articular distal radius fractures using post-operative CT scans to quantify screw protrusion. Pre-operative CTs from this cohort were now used for 3DVP by three experienced orthopaedic trauma surgeons (supplementary video). 3DVP was compared with the corresponding post-operative CT for assessing screw lengths and incidence of dorsal penetration. The Wilcoxon Signed Ranks test was used to compare screw lengths and the Fishers' exact for incidence of penetration.ResultsThree surgeons performed 3DVP for 20 distal radius fractures and virtually applied 60 volar plates and 273 screws. Median screw length was shorter in the 3DVP when compared to IPC: 18 mm (range, 12-22) versus 20 mm (range, 14-26) (p < 0.001). The number of penetrating screws was 5% (13/273 screws) in the 3DVP group compared to 11% (10/91 screws) in the IPC (p = 0.047). Corresponding to a reduction in incidence of at least one dorsally penetrating screw in 40% of patients in the IPC group, to 18% in the 3DVP group (p = 0.069).ConclusionThree-Dimensional Virtual Pre-Operative Planning (3DVP) may reduce the incidence of dorsally penetrating screws in patients treated with volar plating for intra-articular distal radius fractures.Level Of EvidenceII, diagnostic imaging study.© 2021. The Author(s).
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.