Anaesth Intensive Care · Oct 1999
Supplementary oxygen and the laryngeal mask airway--evaluation of a heat-and-moisture exchanger.
- R M Orme and M Williams.
- Department of Anaesthesia, Royal Devon and Exeter Hospital, United Kingdom.
- Anaesth Intensive Care. 1999 Oct 1; 27 (5): 509-11.
AbstractHeat-and-moisture exchangers (HMEs) are routinely used in anaesthesia for the humidification and warming of inspired gases. The use of the Laryngeal Mask Airway (LMA) is widespread, and many anaesthetists choose to leave it in situ until the patient regains consciousness. In this study, we have investigated the effectiveness of an HME as a means of administering supplemental oxygen via LMA in the immediate postoperative period. Oxygen was administered at varying flow rates via the gas sampling port of the HME and the oxygen delivery recorded, using end-tidal oxygraphy as a measure of alveolar PO2. At an oxygen flow rate of 4 l.min-1, the HME provided a mean end-tidal oxygen concentration of 36.2% (+/- 6.2), which compares favourably to other previously described devices. The HME thus represents a convenient, effective and economical means of oxygen supplementation via the LMA.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.