-
Eur J Cardiothorac Surg · Apr 2019
Surgical smoke: still an underestimated health hazard in the operating theatre.
- Gregor J Kocher, Sergio B Sesia, Felipe Lopez-Hilfiker, and Ralph A Schmid.
- Division of General Thoracic Surgery, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland.
- Eur J Cardiothorac Surg. 2019 Apr 1; 55 (4): 626-631.
ObjectivesSmoke generated from electrocautery dissection contains irritating and/or carcinogenic components. The aim of this study was to investigate the effectiveness of a mobile smoke evacuation system (SES) in protecting surgical personnel from these hazardous fumes.MethodsStandardized cuts with an electrocautery device were performed on fresh porcine tissue, and the generated surgical fume was analysed with and without the additional use of a mobile SES using a real-time proton-transfer-reaction time-of-flight mass spectrometer. Furthermore, 2 different surgical masks were tested to investigate their filter capacity.ResultsSeveral toxic and/or carcinogenic volatile organic compounds including 1,3-butadiene, benzene and furfural were found in concentrations clearly above the limits that were set by the National Institute of Occupational Safety and Health: 1,3-butadiene at 19.06 ± 1.54 ppm (limit: 5 ppm), benzene at 6.21 ± 1.33 ppm (limit: 0.5 ppm) and furfural at 14.34 ± 2.97 ppm (limit: 2 ppm). Although the mobile SES was able to reduce these substances to a certain degree, butadiene and benzene still remained above the permissible exposure limits with concentrations of 14.21 ± 0.07 and 1.16 ± 0.05, respectively. Both surgical masks were unable to reduce the 'inhaled' concentrations of volatile organic compounds.ConclusionsAlthough the SES reduced the concentrations of most of the detected volatile organic compounds to a certain amount, especially the carcinogenic substances, butadiene and benzene remained high above exposure limits. According to the abovementioned significant data, further investigation on this topic is imperative, especially when considering that surgical masks were absolutely ineffective in protecting individuals from the toxic smoke and that the cautery was only used for 10 s in this experiment.© The Author(s) 2018. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.