-
- Guang Chu, Wenyi Yang, Guobing Zhang, Zhi Zhang, Shaowen Liu, Baogui Sun, and Fang Wang.
- Department of Cardiology, Shanghai Jiaotong University, First People's Hospital, Shanghai, PR China.
- Med Princ Pract. 2014 Jan 1; 23 (4): 313-7.
ObjectiveTo assess the safety and efficacy of the StarClose device following intra-aortic balloon pump (IABP) counterpulsation using 8-Fr femoral sheaths.Subjects And MethodsFrom June 2008 to August 2012, 42 consecutive patients who received IABP implantation via common femoral artery (CFA) punctures with an 8-Fr sheath (which were then sealed with the StarClose Vascular Closure System at the bedside) were included in this retrospective single-arm study. All the patients underwent duplex control of the puncture site 24 h after deployment of the device, in order to determine the presence or absence of vascular complications including hematoma, pseudoaneurysm, arteriovenous fistula and arterial/venous thrombosis or stenosis. The safety end points were the vascular complications during the hospital stay, and the efficacy end points included device and procedure success.ResultsThe procedure success rate was 92.9% (39/42) and the device success rate was 88.1% (37/42). Major vascular complications occurred in 3 (7.1%) patients; 1 developed a massive hematoma >10 cm which was managed by blood transfusion and surgical reconstruction, and the other 2 developed pseudoaneurysm which was cured by ultrasound-guided thrombin injection or manual compression. Minor vascular complications occurred in 5 (11.9%) patients, including blood oozing in 2, hematoma <5 cm in 2 and severe pain in the remaining patient.ConclusionCFA closure with the StarClose device was safe, feasible and effective in patients undergoing IABP support using 8-Fr sheath sizes.© 2014 S. Karger AG, Basel.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.