• Der Unfallchirurg · Feb 2009

    [A new total knee arthroplasty with physiologically shaped surfaces. Part 2: First clinical results].

    • K-H Frosch, H Nägerl, D Kubein-Meesenburg, J Buchholz, J Dörner, H Dathe, O Hellerer, C Dumont, and K M Stürmer.
    • Abteilung Unfallchirurgie, Plastische and Wiederherstellungschirurgie , Universitätsmedizin Göttingen , Robert-Koch-Str. 40, 37075 Göttingen, Deutschland. khfrosch@med.uni-goettingen.de
    • Unfallchirurg. 2009 Feb 1; 112 (2): 176-84.

    AbstractThe human medial tibial plateau is concave, whereas the lateral tibial plateau is convex. In a normal knee, the convex femoral condyles roll and glide on the tibia during the standing phase of walking. The designs of most commercially available knee prostheses do not take this morphological feature into consideration. The novel design of the AEQUOS G1 knee replacement prosthesis is based on the natural anatomy of the knee joint, with a convex lateral tibia plateau and a sagittal offset of the medial and lateral compartments. Following extensive development and testing, initial clinical results of the AEQUOS G1 prosthesis in a mulitcenter study are presented. From Mai 2005 to March 2007, 158 patients in 4 clinics underwent total knee arthroplasty with the AEQUOS G1 and agreed to participate in the study. Patients were evaluated preoperatively and at 3, 6 and 12 months of follow-up using a standardized protocol that included the American Knee Society Score (AKSS), the Oxford Knee Score (OKS) and the Visual Analog Scale (VAS) for pain. After 3 months, 151 patients appeared for follow up appointments, after 6 months, 134, and after 12 months, 127. The mean range of motion preoperatively was 97.0 degrees (+/-19.9 degrees ) and 107.5 degrees (+/-15.9 degrees ) 12 months after surgery. The AKSS, as well as the modified OKS, significantly improved (p<0.0001) from preoperative scores of 98.8 (+/-35.8) and 37.3 (+/-6.9) points, respectively, to 165.8 (+/-34.1) and 21.9 (+/-7.8) points, preoperatively, and 12 months postoperatively. The VAS score significantly decreased (p<0.001) from 7.4 (+/-1.8) points preoperatively to 1.9 (+/-2.2) points 12 months postoperatively.One implant was revised because of arthrofibrosis and another due to patellar luxation. Two patients required revision because their implants revealed malalignement with ligamentous instability. No infections, aseptic loosening or other implant-specific complications were observed at this early follow-up. Good clinical results were observed at early follow-up with the AEQUOS G1 knee arthroplasty. However, longer follow-up is necessary for a general evaluation of the implant.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.