-
- C Hessler, U Schmucker, G Matthes, A Ekkernkamp, R Gütschow, and C Eggers.
- Abteilung für Unfall- und Wiederherstellungschirurgie, Klinikum der Ernst-Moritz-Arndt-Universität, Sauerbruchstrasse, 17475 Greifswald, Deutschland. christian.hessler@uni-greifswald.de
- Unfallchirurg. 2006 Oct 1; 109 (10): 867-70, 872-4.
BackgroundFixed-angle implants are being increasingly used in surgery of fractures of the proximal humerus. The aim of this retrospective investigation was to evaluate the outcome after fracture reduction utilizing a fixed-angle plate (Königsee).Materials And MethodsBetween January 2003 and April 2004, 58 patients were operated, 52 of whom received a fixed-angle implant; 46 cases were harvested for a follow-up examination. Each patient was re examined clinically and radiologically at least 6 and 18 months after surgery. The functional outcome was evaluated using the Constant Score and the Simple Shoulder Test. The results were compared to results of other investigations.ResultsThe mean patient age was 68.8 years (34-94 years). Fractures were classified using the Neer Classification: 12 were classified as two-part, 25 as three-part, and 9 as four-part fractures. Three of the three-part and four of the four-part fractures were rated as luxation fractures. The overall functional outcome of all cases was good. More than 18 months after surgery the mean general "Constant Score" was 57; the mean side-related "Constant Score" was 89%. The Simple Shoulder Test revealed a pain-free range of motion in 41 (89.1%) of the individuals. The majority of the patients were satisfied with the results regarding remaining range of activity of the injured limb. In five cases significant complications occurred. In two cases the head of the humerus collapsed, and in one case a necrosis of the head occurred. In one individual the implant broke after an additional trauma. In this case a re-osteosynthesis utilizing a tibia plate was performed and the patient was excluded from further follow-up investigations. One soft tissue infection occurred after initial surgery.ConclusionIt has been shown that results after fixation of proximal humerus fractures with fixed-angle implants are good. The functional outcome is good and complications are rare. Our results correlate with other investigations regarding fracture reduction using fixed-angle plates and nails.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.