-
J Am Soc Echocardiogr · Apr 2014
Comparative StudyIncremental value of the en face view of the tricuspid valve by two-dimensional and three-dimensional echocardiography for accurate identification of tricuspid valve leaflets.
- Ivan Stankovic, Ana Maria Daraban, Ruta Jasaityte, Aleksandar N Neskovic, Piet Claus, and Jens-Uwe Voigt.
- Department of Cardiovascular Diseases, University Hospital Gasthuisberg, Catholic University Leuven, Leuven, Belgium; Department of Cardiology, Clinical Hospital Centre Zemun, Faculty of Medicine, University of Belgrade, Belgrade, Serbia.
- J Am Soc Echocardiogr. 2014 Apr 1; 27 (4): 376-84.
BackgroundIn this study, advanced postprocessing of three-dimensional echocardiographic (3DE) data sets was used to identify tricuspid valve (TV) leaflets in two-dimensional echocardiographic (2DE) views, and the feasibility of the subcostal view to obtain 2DE en face views of the TV, as an alternative imaging option to image reconstruction from 3DE imaging, was also tested.MethodsIn 155 consecutive patients, attempts were made to obtain the en face view of the TV by 2DE imaging (from the subcostal window) and by reconstruction from 3DE imaging. Using both in-house-developed and commercially available software for postprocessing of 3DE data, image planes from the standard 2DE views were reconstructed and TV leaflets identified in each view.ResultsWith 2DE imaging, all TV leaflets could be visualized in 58% of patients, compared with 56% using 3DE imaging. In 30 patients (19%), en face views of the TV could be obtained only by 3DE imaging. The anterior leaflet was the largest one in 90% of patients, and the smallest leaflet was either the posterior (49%) or septal (41%) leaflet. In 12% of patients, the TV was either bicuspid or quadricuspid. In patients with pacemakers, the position of the right ventricular lead relative to the TV leaflets was readily determined using both imaging techniques. Visible TV leaflets varied in all standard 2DE views because of variability in image planes and leaflet morphology.ConclusionsHigh variability in TV leaflet anatomy and the dependence on transducer position do not allow schematic leaflet identification. All existing TV leaflet identification schemes are therefore only partially correct, and if correct leaflet identification is needed, the use of an en face view is recommended.Copyright © 2014 American Society of Echocardiography. Published by Mosby, Inc. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.