Randomized Controlled Trial Multicenter Study Comparative Study Clinical Trial
The "Glucositter" overnight automated closed loop system for type 1 diabetes: a randomized crossover trial.
- Revital Nimri, Thomas Danne, Olga Kordonouri, Eran Atlas, Natasa Bratina, Torban Biester, Magdalena Avbelj, Shahar Miller, Ido Muller, Moshe Phillip, and Tadej Battelino.
- The Jesse Z and Sara Lea Shafer Institute for Endocrinology and Diabetes, National Center for Childhood Diabetes, Schneider Children's Medical Center of Israel, Petah Tikva, Israel.
- Pediatr Diabetes. 2013 May 1; 14 (3): 159-67.
BackgroundTight glucose control is needed to prevent long-term diabetes complications; this is hindered by the risk of hypoglycemia, especially at night.ObjectiveTo assess the safety and efficacy of the closed-loop MD-Logic Artificial Pancreas (MDLAP), controlling nocturnal glucose levels in patients with type 1 diabetes mellitus (T1DM).Research Design And MethodsThis was a randomized, multicenter, multinational, crossover trial conducted in Slovenia, Germany, and Israel. Twelve patients with T1DM (age 23.8 ± 15.6 yr; duration of diabetes 13.5 ± 11.9 yr; A1c 8.1 ± 0.8%, mean ± SD) were randomly assigned to participate in two sequential overnight sessions: one using continuous subcutaneous insulin infusion (CSII) and the other, closed-loop insulin delivery by MDLAP. The primary outcome was the number of hypoglycemic events below 63 mg/dL. Endpoints analyses were based on sensor glucose readings.ResultsThree events of nocturnal hypoglycemia occurred during CSII and none during the closed-loop control (p = 0.18). The percentage of time spent in the near normal range of 63-140 mg/dL was significantly higher in the overnight closed-loop sessions [76% (54-85)] than during CSII therapy [29% (11-44)] [p = 0.02, median (interquartile range)]. The mean overnight glucose level was reduced by 36 mg/dL with closed-loop insulin delivery (p = 0.02) with a significantly less glucose variability when compared with the CSII nights (p < 0.001).ConclusionThe results of this study demonstrate the ability of the MDLAP to safely improve overnight glucose control without increased risk of hypoglycemia in patients with T1DM at three different national, geographic, and clinical centers (ClinicalTrials.gov number, NCT 01238406).© 2013 John Wiley & Sons A/S.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:

- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.