• Magn Reson Med · Jul 2021

    Simultaneous T1 , T2 , and T1ρ relaxation mapping of the lower leg muscle with MR fingerprinting.

    • Azadeh Sharafi, Katherine Medina, Marcelo W V Zibetti, Smita Rao, Martijn A Cloos, Ryan Brown, and Ravinder R Regatte.
    • Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University Grossman School of Medicine, New York, New York, USA.
    • Magn Reson Med. 2021 Jul 1; 86 (1): 372-381.

    PurposeTo develop a novel MR-fingerprinting (MRF) pulse sequence that is insensitive to B 1 + and B0 imperfections for simultaneous T1 , T2 , and T1ρ relaxation mapping.MethodsWe implemented a totally balanced spin-lock (TB-SL) module to encode T1ρ relaxation into an existing MRF framework that encoded T1 and T2 . The spin-lock module used two 180° pulses with compensatory phases to reduce T1ρ sensitivity to B1 and B0 inhomogeneities. We compared T1ρ measured using TB-SL MRF in Bloch simulations, model agar phantoms, and in vivo experiments to those with a self-compensated spin-lock preparation module (SC-SL). The TB-SL MRF repeatability was evaluated in maps acquired in the lower leg skeletal muscle of 12 diabetic peripheral neuropathy patients, scanned two times each during visits separated by about 30 days.ResultsThe phantom relaxation times measured with TB-SL and SC-SL MRF were in good agreement with reference values in regions with low B1 inhomogeneities. Compared with SC-SL, TB-SL MRF showed in experiments greater robustness against severe B1 inhomogeneities and in Bloch simulations greater robustness against B1 and B0 . We measured with TB-SL MRF an average T1 = 950.1 ± 28.7 ms, T2 = 26.0 ± 1.2 ms, and T1ρ = 31.7 ± 3.2 ms in skeletal muscle across patients. Bland-Altman analysis demonstrated low bias between TB-SL and SC-SL MRF and between TB-SL MRF maps acquired in two visits. The coefficient of variation was less than 3% for all measurements.ConclusionThe proposed TB-SL MRF sequence is fast and insensitive to B 1 + and B0 imperfections. It can simultaneously map T1 , T2 , T1ρ , and B 1 + in a single scan and can potentially be used to study muscle composition.© 2021 International Society for Magnetic Resonance in Medicine.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…