    Pilot study on harmonization of cardiac troponin I immunoassays using patients and quality control plasma samples. On behalf of the Italian Section of the European Ligand Assay Society (ELAS) and of the Study Group on Cardiovascular Biomarkers of the Società Italiana di Biochimica Clinica (SIBioC).

    • Aldo Clerico, Andrea Ripoli, Silvia Masotti, Concetta Prontera, Simona Storti, Antonio Fortunato, Paola Buzzi, Ivo Casagranda, Maria Franzini, Rudina Ndreu, Gian Carlo Zucchelli, Martina Zaninotto, and Mario Plebani.
    • Fondazione CNR Regione Toscana G. Monasterio, Pisa, Italy; Scuola Superiore Sant'Anna, Pisa, Italy.
    • Clin. Chim. Acta. 2016 May 1; 456: 42-48.

    BackgroundThe aim of this study is to evaluate whether it is possible to reduce the between-methods variability of troponin I (cTnI) immunoassays using mathematical algorithms calculated from the results of both patients' samples and quality control materials distributed in an external quality assessment (EQA) scheme.MethodsWe collected 122 heparinized plasma samples of patients admitted to the emergency department with thoracic pain or supraventricular tachyarrhythmia. Moreover, we also analyzed 20 control samples distributed in an EQA and 26 plasma pools prepared from healthy subjects and patients with myocardial infarction. We evaluated 4 different methods for cTnI assay: STAT Architect High Sensitive TnI (Abbott Diagnostics), ADVIA Centaur Troponin I Ultra (Siemens Healthcare Diagnostics), ST AIA-Pack cTnI Third Generation (Tosoh Bioscience), and Access AccuTnI+3 (Beckman Coulter Diagnostics).ResultsSystematic differences between cTnI methods were observed. However, correlation coefficients (R from 0.976 to 0.990) between the log-transformed cTnI values measured in all 168 samples were significantly better (p=0.0037) than those obtained considering only the 122 patients' samples. cTnI values measured in EQA and pool samples were included within the 95% prediction intervals of linear regressions calculated with those of patients' samples. After the recalibration of cTnI values based on the robust principal component analysis approach the between-methods variability decreased significantly (about 40% around the cut off values).ConclusionsOur pilot study suggests that EQA schemes for cTnI immunoassay methods, based on both quality control samples with tested commutability and robust statistical analyses, are able to evaluate between-methods variability as well as allow a reliable recalibration and harmonization of results.Copyright © 2016 Elsevier B.V. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…