• J Appl Lab Med · Mar 2019

    Analytical Concordance of Diverse Point-of-Care and Central Laboratory Troponin I Assays.

    • TsuiAlbert K YAKYDepartment of Laboratory Medicine and Pathology, University of Alberta, Edmonton, AB, Canada; atsui@ualberta.ca.Department of Laboratory Medicine and Pathology, Alberta Health Services, Edmonton, AB, Canada., Martha E Lyon, Sean van Diepen, Bobbi Lynn Goudreau, Dylan Thomas, Trefor Higgins, Joshua E Raizman, Anna K Füzéry, Karina Rodriguez-Capote, Mathew Estey, and George Cembrowski.
    • Department of Laboratory Medicine and Pathology, University of Alberta, Edmonton, AB, Canada; atsui@ualberta.ca.
    • J Appl Lab Med. 2019 Mar 1; 3 (5): 764-774.

    BackgroundCardiac troponin I (cTnI) 99th percentile cutoffs, used in the diagnosis of acute myocardial infarction, are not standardized across cTnI assays. We compared 3 point-of-care (POC) and 1 central laboratory contemporary cTnI assays against the Abbott high-sensitivity (hs) cTnI to evaluate the analytical concordance and the feasibility of using a single cutoff value for all assays.MethodsFresh blood samples collected from 102 inpatients in the coronary care unit were measured on central laboratory instruments (Beckman Coulter DxI AccuTnI+3 TnI, Abbott Architect hs-TnI) and cTnI POC analyzers (Alere Triage Troponin I, Radiometer AQT90, Abbott i-STAT). Agreement and correlation between the contemporary cTnI assays and hs-cTnI assay were assessed using regression analysis. Proportional bias was assessed using Bland-Altman plots. Concordance between the contemporary cTnI and hs-cTnI assays was determined by diagnostic contingency tables at specific cutoffs.ResultsMost POC cTnI assays had excellent correlation with the Abbott hs-cTnI method (r 2 = 0.955-0.970) except for Alere Triage (r 2 = 0.617), while proportional bias is evident between all cTnI assays. Overall concordance between POC contemporary cTnI assays and hs-cTnI assay was 80% to 90% at their respective 99th percentile cutoffs. The concordance increased to 90% to 95% when a fixed cutoff of 0.03 to 0.05 ng/mL was used across the assays.ConclusionsThis study demonstrates poor analytical concordance between cTnI assays at the 99th percentile and supports the notion of a single clinical decision limit for cTnI and consequently standardization of diagnostic protocols despite the analytical differences among these assays.© 2018 American Association for Clinical Chemistry.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…