• Arch Intern Med · Apr 1997

    The stethoscope. A potential source of nosocomial infection?

    • M A Marinella, C Pierson, and C Chenoweth.
    • Department of Internal Medicine, University of Michigan Medical Center, Ann Arbor, USA.
    • Arch Intern Med. 1997 Apr 14;157(7):786-90.

    BackgroundStethoscope diaphragms have been shown to harbor potentially pathogenic bacteria.ObjectivesTo assess bacterial contamination on the diaphragm and under the plastic rim that secures the diaphragm of stethoscopes of physicians, nurses, medical students, and house staff in an intensive care unit and a general medical ward of a large university hospital. Also to compare the effectiveness of various cleaning agents and assess the transmissibility of bacteria from contaminated stethoscopes to human skin.MethodsAerobic and anaerobic bacterial cultures were performed on 40 randomly selected stethoscopes. We compared the effects of isopropyl alcohol, sodium hypochlorite (bleach), and benzalkonium chloride swabs, as well as soap and water, on reducing bacterial contamination on the stethoscope diaphragm and under the rim. The transmissibility of Micrococcus luteus inoculated onto a stethoscope diaphragm to clean human skin was also determined.ResultsEleven genera and species of bacteria were isolated, with coagulase-negative staphylococcus present on 100% of stethoscopes and Staphylococcus aureus on 38%. Clostridium difficile was not isolated. The mean (+/-SE) number of total colony-forming units was 158 +/- 33 per diaphragm and 289 +/- 54 per rim. Physicians' stethoscope diaphragms had significantly more colony-forming units of coagulase-negative staphylococci than those of nurses: 163 +/- 44 vs 50 +/- 12, respectively (P = .02). The most effective cleaning agent was isopropyl alcohol after cleaning the diaphragm surface, the stethoscope diaphragms contained 0.2 +/- 0.2 colony-forming units and the rims contained 2.2 +/- 1.5 colony-forming units (P = .01). In addition, M luteus was transferred from inoculated stethoscopes to human skin.ConclusionsMost stethoscopes harbor potential pathogens but are not a source of C difficile. Physicians' stethoscopes generally had a higher bacterial load than nurses' stethoscopes. Isopropyl alcohol is an effective cleaning agent when applied to the stethoscope diaphragm. Stethoscopes transfer M luteus to human skin, making it likely that other bacteria can be transferred as well.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…