• Int Orthop · Aug 2016

    Reversed distal femoral locking plate for failed proximal femoral nail with non-union of proximal femoral fractures.

    • Raju Vaishya, Amit Kumar Agarwal, Nishint Gupta, and Vipul Vijay.
    • Department of Orthopaedics, Indraprastha Apollo Hospital, Sarita Vihar, Mathura Road, New Delhi, India, 110076.
    • Int Orthop. 2016 Aug 1; 40 (8): 1709-1715.

    IntroductionFailure of proximal femoral fracture managed by proximal femoral nail (PFN) leads to a very difficult situation to handle with conventional techniques, and reversed distal femoral locking compression plate (DF-LCP) is of great benefit in these selective cases.MethodsTwelve patients with ununited proximal femoral fractures including subtrochanteric fractures with a failed PFN implant were included in the study. All patients with periprosthetic fractures and fractures treated by implants other than PFN were excluded from this study.ResultAll fractures went into union in an average time of nine months and 15 days with no implant failures. The mean time of re-osteosynthesis after the primary index surgery of PFN was one year eight months. Mean surgical time of re-osteosynthesis was 110 minutes, and average blood loss during surgery was 550 ml.DiscussionThe PFM is one of the most commonly used implant for unstable proximal femur fractures. The use of PFN is technically demanding and is associated with high failure rates. Although dynamic compression screw (DCS), proximal femoral locking plate (PF-LCP) and other implants can be used in these failed situations, they are associated with a high complication rate. The reversed DF-LCP is a rescue implant for these complex situations. Apart from anatomical and biomechanical advantages, there are several other clinical benefits of using DF-LCP.ConclusionWe conclude that DF-LCP is a potential and safe implant of choice for the management of nonunion associated with failed PFN. It may be considered an implant of choice as rescue from such a complex situation. It offers several anatomical, biomechanical and clinical advantages over other available conventional implants.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…