-
Comparative Study
Intensity modulation with photons for benign intracranial tumours: a planning comparison of volumetric single arc, helical arc and fixed gantry techniques.
- Antonella Fogliata, Alessandro Clivio, Giorgia Nicolini, Eugenio Vanetti, and Luca Cozzi.
- Oncology Institute of Southern Switzerland, Radiation Oncology Department, Bellinzona, Switzerland.
- Radiother Oncol. 2008 Dec 1; 89 (3): 254-62.
Background And PurposeThe potential benefits and limitations of the new RapidArc treatment concept compared to Helical Tomotherapy and fixed gantry intensity modulation techniques have been assessed at treatment planning level on 12 patients presenting with 'benign' brain tumours.Materials And MethodsPlans for five acoustic neurinomas, five meningiomas and two pituitary adenomas were computed for an Helical Tomotherapy (HT) unit, for RapidArc delivery (RA) on a linac equipped with two types of MLC (RA_HD120 with the new High Definition MLC with 2.5mm leaf width at isocentre and RA_M120 with the standard Millennium with 5mm resolution) and for fixed beam IMRT with the High Definition MLC. Analysis was mostly performed on physical quantities derived from Dose-Volume Histograms (DVHs).ResultsTarget coverage resulted basically equivalent among techniques. V(95%) (in %) was higher than 99% for all techniques, minimum significant dose (D(99%)) was 95.5+/-1.4 for IMRT, 96.2+/-1.4 and 97.0+/-1.2 for the RA_HD120 and RA_M120 approaches and 96.8+/-1.7 for HT, maximum significant dose (D(1%), in %) was 102.2+/-0.8, 102.7+/-0.5, 102.4+/-0.5 and 103.0+/-1.1, respectively, standard deviation (in %) was 1.4+/-0.4, 1.3+/-0.3, 1.1+/-0.2 and 0.8+/-0.3, respectively. Conformity Index (CI(95%)) was 0.47+/-0.12, 0.46+/-0.12, 0.43+/-0.11 and 0.38+/-0.11, respectively. For organs at risk all techniques respected planning objectives. Concerning the healthy tissue: V(10 Gy) (in %) was 9.4+/-5.5, 9.9+/-6.1, 9.2+/-6.1 and 12.1+/-8.8, respectively. Integral dose measured on the healthy tissue was 7.5+/-3.3, 9.7+/-3.4, 8.7+/-3.4, 10.4+/-4.2 10(3) Gy cm(3), respectively.ConclusionsFor the class of tumours investigated in this report, HT and RA and IMRT proved to be adequate to properly treat patients. Further studies on more complex cases need to be investigated in order to assess the effectiveness of this new technique in a broader clinical perspective.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.