• Yonsei medical journal · Nov 2021

    Transcatheter Aortic Valve Replacement with Minimal Contrast Dye in Patients with Renal Insufficiency.

    • Jah Yeon Choi, Geu-Ru Hong, Sung-Jin Hong, Chi Young Shim, Chul-Min Ahn, Jung-Sun Kim, Byeong-Keuk Kim, Young-Guk Ko, Donghoon Choi, Yangsoo Jang, and Myeong-Ki Hong.
    • Cardiovascular Center, Korea University Guro Hospital, Korea University College of Medicine, Seoul, Korea.
    • Yonsei Med. J. 2021 Nov 1; 62 (11): 990-996.

    PurposeConcerns have been consistently raised in regards to the considerable amount of contrast dye used during transcatheter aortic valve replacement (TAVR) in patients with renal insufficiency. In the present study, we introduced minimal contrast TAVR and compared its 30-day clinical outcomes with conventional TAVR.Materials And MethodsWe retrospectively investigated 369 patients who underwent TAVR between July 2011 and April 2020 in our institute. Among them, 93 patients with severe aortic stenosis and renal insufficiency (estimated glomerular filtration rate ≤50 mL/min/1.73 m²) were included and divided into a conventional TAVR group (n=56) and a minimal contrast TAVR group (n=37). In the minimal contrast TAVR group, the total amount of contrast was <10 mL during the entire TAVR procedure. Thirty-day major adverse clinical events (MACE), including death, stroke, implantation of permanent pacemaker, and initiation of hemodialysis, were investigated.ResultsThe incidence of MACE was significantly lower in the minimal contrast TAVR group than the conventional TAVR group (16.2% vs. 42.9%, p=0.010). Death occurred in 9 patients (16.1%) in the conventional TAVR group and in 0 patients in the minimal contrast group (p=0.011). Hemodialysis was initiated in 2 patients (5.4%) in the minimal contrast TAVR group and in 7 patients (12.5%) in the conventional TAVR group (p=0.256). Multivariate regression analysis showed that the minimal contrast TAVR procedure was an independent predictor for reducing MACE (hazard ratio 0.208, 95% confidence interval: 0.080-0.541, p=0.001).ConclusionMinimal contrast TAVR is feasible and shows more favorable short-term clinical outcomes than conventional TAVR in patients with renal insufficiency.© Copyright: Yonsei University College of Medicine 2021.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…