-
J Magn Reson Imaging · Jul 2018
Rotator cuff tendon assessment using magic-angle insensitive 3D ultrashort echo time cones magnetization transfer (UTE-Cones-MT) imaging and modeling with histological correlation.
- Yanchun Zhu, Xin Cheng, Yajun Ma, Jonathan H Wong, Yaoqin Xie, Jiang Du, and Eric Y Chang.
- Department of Radiology, University of California, San Diego Medical Center, San Diego, California, USA.
- J Magn Reson Imaging. 2018 Jul 1; 48 (1): 160-168.
BackgroundRotator cuff tendons (RCTs) are challenging to image due to the "magic angle effect" and their short T2 .PurposeTo assess the degree of magic angle sensitivity of human RCTs and to utilize a 3D ultrashort echo time Cones sequence with magnetization transfer preparation (UTE-Cones-MT) and two-pool quantitative MT modeling with histological correlation. We hypothesized that MT parameters would be less sensitive to the magic angle compared with conventional T2 measurements.Study TypeProspective imaging pathologic correlation.SpecimenTwenty cadaveric rotator cuff tendons were imaged at five sample orientations ranging from 0-90° relative to the B0 field.Field Strength/Sequence3T/3D UTE-Cones-MT and Carr-Purcell-Meiboom-Gill (CPMG).AssessmentTwo-pool quantitative MT modeling parameters and T2 values were calculated in regions of interest drawn by a medical physicist. Histopathological analysis was performed and mild and severe tendinopathy groups were assigned by a histopathologist and histotechnician.Statistical TestsCoefficients of variations (CVs) were calculated for measures between the different orientations and group means were compared for each measure.ResultsCVs of T2 and macromolecular fractions between orientations were 26.14 ± 16.82% and 6.18 ± 2.77% (mean ± SD), respectively. T2 measurements at 0°, 27°, 70°, and 90° showed significant differences between the two histological groups (P = 0.004, 0.008, 0.003, and 0.015, respectively), but not at 55° (P = 0.611). Mean T2 value ranges between orientations for the mild and severe tendinopathy groups were 15.27-30.32 msec and 20.81-35.85 msec, respectively, showing overlap despite statistically significant differences (P = 0.003). Macromolecular fractions at all angles showed significant differences between the two groups (P < 0.0001). Mean fraction ranges between orientations for the mild and severe tendinopathy groups were 14.32-17.17% and 10.00-13.75% respectively (P < 0.0001) with no overlap.Data ConclusionCompared with T2 , macromolecular fraction obtained with the 3D UTE-Cones-MT technique is resistant to the magic angle effect and is more sensitive to RCT degeneration.Level Of Evidence1 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2017.© 2017 International Society for Magnetic Resonance in Medicine.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.