• Int J Occup Med Environ Health · Jan 2015

    Estimation of operators' fatigue using optical methods for determination of pupil activity.

    • Krzysztof Różanowski, Michał Bernat, and Agnieszka Kamińska.
    • Military Institute of Aviation Medicine, Warszawa, Poland (Aviation Bioengineering Department).
    • Int J Occup Med Environ Health. 2015 Jan 1; 28 (2): 263-81.

    IntroductionThe purpose of this study was to develop and initially validate an objective, yet quick, method for assessment of human fatigue. This aim can be achieved by the use of an optical, non-contact method of analysis of pupil activity. The study involved 2 phenomena typical for the behavior of the human pupil: pupillary reflex and pupillary movements. The 1st phenomenon is related to the pupillary light reflex (PLR), which presents the results of physiological adaptation mechanisms of the human eye. The pupillary unrest index (PUI) is an additional parameter referring to the tendency for instability of the pupil.Material And MethodsIndicators of these 2 mechanisms were assessed under the same experimental laboratory conditions. Assessment was conducted on a group of volunteers (N = 10) during 4 controlled series of measurements performed at night. Pupillary reflex parameters associated with PLR and pupillary unrest index (PUI) were recorded using F²D Fit-For-Duty, a commercially available system made by AMTech Pupilknowlogy GmbH. Baseline pupil diameter, oscillations, reflex latency, maximum reaction time, pupil constriction time, pupil dilation time, and constriction amplitude were recorded.ResultsAs a result of the study, we were able to demonstrate correlation and confirm the usefulness of PLR and PST methods in the assessment of sleep deprivation. Parameters of PLR that may indicate human fatigue were identified. The effect of light impulse sequences on the dynamics of pupillary reflex and the relationship between PUI (pupillary unrest index) measurement duration and sleepiness assessment validity, were assessed.ConclusionsThe results of the pilot studies were sufficient to develop minimum requirements for a PLR sensor that would be capable of estimating the level of fatigue with accuracy of a PUI method, but at a 5 times faster rate.This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,704,841 articles already indexed!

We guarantee your privacy. Your email address will not be shared.